Solutions for Demanding Applications Industrial Flat Panel Displays VT084 DiamondVue/CrystalVue Series 8.
User’s Guide Read these instructions completely before attempting to operate your new LCD Color Display. Table Of Contents Page Section 1 Page Section 4 Introduction 3 Touch screen 10 1.1 VT084 Series Features 3 4.1 Touch Screen Introduction 10 1.2 Product Safety Precautions 3 4.2 Touch Screen Installation 10 Section 2 Section 5 Display Setup 4 2.1 Inspection 4 2.2 Unpacking 4 Section 6 2.3 Included Parts 4 6.1 Cleaning & Maintenance 2.4 Connecting The Display 4 2.
INTRODUCTION SECTION 1 1.1 VT084 Series Features The VT084 Series is capable of displaying 16.8M colors in a continuous spectrum. The VT084 Series provides a standard VGA input, a DVI-D input, an S-Video input, and a Composite input. The VT084 Series is auto synchronous adjusting the display to the appropriate VGA input. The VT084 Series is available in Chassis Mount, Panel Mount, and Wall Mount configurations.
DISPLAY SETUP SECTION 2 2.1 Inspection of your VT084 display The VT084 is supplied with different accessories depending on the model configuration purchased. Verify the VT084 and accessories are what were ordered. Contact your Vartech salesperson should there be any discrepancies. 2.2 Unpacking and setting up your VT084 display Your LCD monitor package will consist of the components listed below. Open shipping container and place all the components on a flat clean surface. 2.
The power source is incorrect. The unit is malfunctioning. If you believe this to be true, disconnect the video cable from the LCD display and connect to a known working display. If the display is working satisfactory and the video is within the appropriate range, then contact Vartech Customer service for a RMA number at 800-223-8050. 2.
Separate Horizontal and Vertical Sync. Use the three video connectors plus the horizontal sync/ composite sync and vertical sync input. X X X X X GETTING STARTED SECTION 3 3.
3.
Select SECAM video system Wide screen mode information display# Select the input mode (1280 / 1360 / 1366 / 1368) to recognize and display the correct input signal information display on the OSD menu. 1280 : 1280x768 1360 : 1360x768 Exit Brightness and Contrast Brightness Contrast Saturation* Hue* Exit 1366: 1366x768 1368: 1368x768 Exit the OSD menu and save the settings Increase/decrease brightness level. Press – or + (Increase/decrease panel contrast level. Press – or + (Increase/decrease hue level.
Frequency Adjust the image horizontal size Phase Fine tune the data sampling position (adjust image quality) Image Horizontal Position Use +/- to move the image horizontally Press – or + (Use +/- to move the image vertically Press – or + (Exit the OSD menu Image Vertical Exit +) +) Utilities OSD setting Load Factory Default Sharpness Exit OSD Timeout : 0 / 10 / 20 / 30 / 40 / 50 / 60 seconds (Always on when set to 0) Press – or + (+) OSD menu horizontal position Press – or + (+) OSD menu vertica
TOUCHSCREEN SECTION 4 4.1 Introduction Touch screens are a common means to interface operator inputs to a system. The universal standard of Windows GUI (Graphical User Interface) has significantly increased the use of touch screens. There are five main touch technologies. The technologies are resistive, surface acoustic wave (SAW), capacitive, infrared (IR), and projective capacitive. Each touch technology has advantages and disadvantages based on different user applications. 4.
TROUBLESHOOTING SECTION 5 5.
MAINTENANCE SECTION 6 6.1 Cleaning Occasionally clean the display panel and cabinet with a soft cloth dampened (not soaked) with a mild (non-abrasive) glass cleaner. Keep turning a fresh side of the cloth toward the screen surface to avoid scratching it with accumulated grit. Note: The solvent should be applied only to the cloth, and not directly on the monitor screen. Do not use paper products as they may scratch the surface. To minimize the risk of abrasion, allow the screen to stand dry.
MOUNTING INSTRUCTIONS SECTION 7 7.1 Panel Mount Procedure Mechanical Drawings Model Description VT084P2 8.4" DiamondVue/CrystalVue Panel Mount Drawing (Nema 4) 16 VT084PS2 8.4" DiamondVue/CrystalVue Panel Mount Drawing (Nema 4x) 17 VT084C2 8.4” DiamondVue/CrystalVue Open Frame 18 VT084W2 8.4” DiamondVue/CrystalVue Wall/Vesa Mount 19 Page(s) 1. Cut and drill the panel (refer to panel mount drawing). Measurements are in inches. 2.
SPECIFICATIONS ENGINEERING SPECIFICATIONS – DiamondVue Panel Size 8.4” (21cm) Type Active Matrix Color Thin Film Transistor (TFT) Native Panel Resolution SVGA XGA - Optional Pixel Format 800 (H) x 600 (V) 1024 (H) x 768 (V) Pixel Pitch 0.213 (H) x 0.213 (V) mm 0.1665 (H) x 0.1665 (V) mm Pixel Arrangement RGB (Red dot, Green dot, Blue dot) vertical stripe Dot Pitch 0.071 (H) x 0.213 (V) mm 0.0555 (H) x 0.1665 (V) mm Active Display Area 6.709” x 5.031” 170.4mm x 127.8mm 6.712” x 5.
Storage: Up to 40,000 ft SPECIFICATIONS ENGINEERING SPECIFICATIONS – CrystalVue Panel Size 8.4” (21cm) Type Active Matrix Color Thin Film Transistor (TFT) Native Panel Resolution SVGA XGA - Optional Pixel Format 800 (H) x 600 (V) 1024 (H) x 768 (V) Pixel Pitch 0.213 (H) x 0.213 (V) mm 0.1665 (H) x 0.1665 (V) mm Pixel Arrangement RGB (Red dot, Green dot, Blue dot) vertical stripe Dot Pitch 0.071 (H) x 0.213 (V) mm 0.0555 (H) x 0.1665 (V) mm Active Display Area 6.709” x 5.031” 170.
VT084 DiamondVue/CrystalVue User’s Guide 150‐175
VT084 DiamondVue/CrystalVue User’s Guide 150‐175
VT084 DiamondVue/CrystalVue User’s Guide 150‐175
VARTECH SYSTEMS INC. HEADQUARTERS 6399 Amp Drive, Clemmons, NC 27012 Toll-Free: 800.223.8050 International Phone: 001.225.298.0300 Fax: 225.297.2440 E-mail: sales@vartechsystems.com www.vartechsystems.com 01.06.