Datasheet

Primary Lithium Cells
Capacity vs. load resistance
Operating Voltage vs. load resistance*
Temperature Characteristics
¹
Contact VARTA if the application is intended to be outside the
range of -20°C to +70°C.
²
depending on environmental condition and energy consumption
CR 2450
Type Number  ........................
Designation IEC ....................
System ..................................
UL Recognition .....................
Nominal Voltage  ....................
Typical Capacity C ................
Weight (approx.) ....................
Volume ..................................
Coding   ..................................
Temperature Ranges
Storage .................................
Discharge  ..............................
Dimensions
Diameter (A) ..........................
Height (B)  ..............................
Shoulder Diameter [E] ...........
Typical Capacities (at 20°C)
6450
CR 2450
Li-Manganese dioxide /
Organic Electrolyte
MH 13654 (N)
3 V
620 mAh (Load 5,6 kOhm,
at 20°C down to 2 V)
6,2 g
2,3 ccm
Date of Manufacturing
Month/Year
min. max.
-55°C 70°C
-20°C 70°C¹
min. max.
24,20 24,70
4,60 5,00
21,00
Performance Data
Self-dischange rate < 1% at room temperature
Storage life > 10 years
Operating life ² > 10 years
Discharge Type Load End Voltage: 2,0 V
Continuous 5600 Ω Time: 1250 h
24 h/d, 7 d/w Capacity: 620 mAh
Energy: 1730 mWh
*Discharge depth 40%

Summary of content (2 pages)