page 20 | 21
Capacity vs. load resistance
Operating Voltage vs. load resistance*
Temperature Characteristics
¹
Contact VARTA if the application is intended to be outside the
range of -20°C to +70°C.
²
depending on environmental condition and energy consumption
CR 2430
Type Number ........................
Designation IEC ....................
System ..................................
UL Recognition ......................
Nominal Voltage ....................
Typical Capacity C ................
Weight (approx.) ....................
Volume ..................................
Coding ..................................
Temperature Ranges
Storage .................................
Discharge ..............................
Dimensions
Diameter (A) ..........................
Height (B) ..............................
Shoulder Diameter [E] ...........
Typical Capacities (at 20°C)
6430
CR 2430
Li-Manganese dioxide /
Organic Electrolyte
MH 13654 (N)
3 V
300 mAh (Load 5,6 kOhm,
at 20°C down to 2 V)
4 g
1,3 ccm
Date of Manufacturing
Month/Year
min. max.
-55°C 70°C
-20°C 70°C¹
min. max.
24,20 24,50
2,70 3,00
16,30 16,70
*Discharge depth 40%
Performance Data
• Self-dischange rate < 1% at room temperature
• Storage life > 10 years
• Operating life ² > 10 years
Discharge Type Load End Voltage: 2,0 V
Continuous 5600 Ω Time: 600 h
24 h/d, 7 d/w Capacity: 300 mAh
Current [μA] Energy: 840 mWh