Datasheet
3.8 DISCHARGE CHARACTERISTICS OF NIMH HIGH RATE
BUTTON CELLS POWERFUL (85)
The capacity and the voltage level of a cell during dis-
charge are limited by various operational parameters.
The most important of these are: the rate of discharge,
the ambient temperature and the end of discharge
voltage. In general, the higher the discharge current, the
lower the discharge voltage and the available capacity;
this tendency becomes pronounced when the discharge
current reaches 5 CA.
FIG. 34
Temperature characteristics of NiMH
High Rate Button Cells V…HR Multi-
layer-electrodes (ML) at GSM current
profile
Charge: 0.1 CA at room temperature
Discharge: GSM-pulse
(1.8 A – 0.6 msec/0.2 A – 4 msec)
at various temperatures
FIG. 33
Typical discharge curves of NiMH
High Rate Button Cells V…HRT
Multi-layer-electrodes (ML) at room
temperature
Discharge at various rates at 20°C
FIG. 32
Typical temperature characteristics of
NiMH High Rate Button Cells V…HR
Discharge at 0.2 CA
page 34 | 35