Datasheet

Rechargeable Button Cells
3.6 CHARGE TABLE FOR NIMH HIGH RATE BUTTON CELLS V…HR(T)
Specific currents 0.1 CA 0.3 CA 0.5 1 CA 0.01 CA to
0.03 CA
Charge time 14 16 hours 4 hours 1 2 hours unlimited
Recommended charging 0.1 CA 0.3 CA 0.5 1 CA 0.01 CA to
charging values at 14 16 hours 4 hours 0.03 CA
room temperature for the unlimited
powerful family V...HR(T)
Available 100 100 > 80 100
capacity (%)
TAB. 14
1)
Only at room temperature and after fully discharged cells, voltage control
recommended (for multi-layer-electrodes)
2)
Special charge control is required (see p. 26)
Note: NiMH High Rate Button Cells shall not be charged at temperatures below 0°C
Normal
charge
Accelerated
charge
1)
Fast
charge
2)
Trickle
charge
Charge Table
FIG. 25
TYPICAL TRICKLE CHARGING
Figure 25 shows battery voltage and
charge current characteristics over
charging time for a 2-cell battery in a
typical trickle charge circuit
Trickle charge characteristics of e.g.
2/V 18 HRT R
C