Adjustable Radiator and Main Line Vent Valves
for One Pipe Steam Systems
Laboratory Study:
The venting capacity of radiator air vents and main line air vents used
in single pipe steam heating systems has an important effect on the
operation of these systems. In order to obtain a better understanding
of these effects, the Center for Energy and Environment conducted
experiments both in laboratory and in the eld to investigate the
properties of single pipe steam air venting. Commercially available
radiator and main line air vents were tested and compared. Main
line air vents in one building were replaced with open pipe orices
of different sizes, and the resulting ll characteristics of the main
steam lines were observed. The purpose of the main line air vent is
to rapidly vent the relatively large amount of air in the main lines.
This allows the main line to ll more quickly and thus reduces
the time difference of steam arrival at the different risers. A large
orice allows the air to be pushed out as a lower back pressure. The
function of the radiator air vent is to provide a means for air to be
driven out of the radiator as steam enters. At a given pressure, the
ll time of a radiator varies proportional to its heat capacity and
inversely proportional to the venting capacity of the radiator air vent.
It is possible to control the speed at which a radiator will ll with
steam by installing a radiator air vent with a certain venting capacity.
Used in this manner, radiator air vents are helpful in evening out
the heat distribution in a building. The results show that the larger
the vent, the more quickly you can vent a system, which lowers
operating pressure requirements.
Achieve a More Balanced Steam Heating System with the Most
Advanced Air Valve Available.
• Exclusive Fingertip Adjustment: Simply sliding a lever allows you to adjust the venting rate.
• Each Radiator Has Its Own Venting Speed: In hard to heat areas, the radiator VARIVALVES
®
can be adjusted for
quicker venting. In overheated areas, the VARIVALVES
®
can be adjusted for slower venting. This allows steam to be
evenly distributed in the system.
• Long Term Fuel Savings: Because Heat-Timer VARIVALVES
®
vent more quickly, it takes less time to ll your
system with steam. By adjusting the venting to balance the system, there is no need to raise the steam pressure to
reach under heated areas. Shorter boiler runtimes and lower pressure results in fuel savings.
• Replace Valves with VARIVALVES
®
: Using Heat-Timer adjustable vent rate VARIVALVES
®
throughout the
system allows you to balance the heat to your requirements.
VARIVALVE
®