User Manual
FSE103 User Guide
4.2 User integration
If you are not using our user interface, please note that the FSE103 will continuously stream data through the
USB cable as soon as the cable is plugged in. However, no data is saved within the sensor itself.
4.2.1 Connection
The FSE103 is seen as a serial device (COM port) when plugged into a computer. Since the sensor uses a USB
CDC to emulate serial communication through USB protocol, no settings need to be specified when opening
the serial port.
4.2.2 Commands
Two types of data can be sent by the sensor:
• calculated forces
• raw values used to calculate the forces
By default, the FSE103 sends the calculated forces as soon as the cable is plugged in. You can switch between
the two modes by sending the following command:
Name Command
[Default] Stream calculated forces ’f’ or ’F’
Stream raw values ’r’ or ’R’
Initialize sensor ’z’ or ’Z’
© 2016 Variense, Inc. All rights reserved. Page 9