Spec Sheet
FSE103
Application Information
• Capacitive technology provides
enhanced sensitivity without
compromising signal integrity,
resulting in low system noise and
reducing measurement errors.
• USB interface minimizes space (plug
and play). No conversion box needed.
• Return logged serial data with
timestamp feature.
• Intuitive and exible user interface
provides easy-to-use display and
calculation tools.
Technical Specications
071416FSE103EN
JULY 2016
PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2016 VARIENSE INC. ALL RIGHTS RESERVED.
Variense, Inc.
400 Montfort street
H3C 4J9, Montreal, Quebec
Phone: 1 844 827 4367
E-mail: info@variense.com
www.variense.com
CONTACT
21,12
1
3 x M3x0.5
2,50
MOUNTING SURFACE
THREADED HOLES
USB
CONNECTOR
39
10
LOADING SURFACE
AREA
M5x0.8
6
THREADED HOLE
X
Y
V ARIENSE
Z
Y
X
Sensor Mounting Dimensions
TOP SIDE BOTTOM SIDE SIDE VIEW
UNITS: mm
Feature Condition Value Unit Note
Mechanical specifications
Diameter Outer 39 mm
Thickness 21 mm
Weight 40 g
Overload capacity Fx, Fy, Fz 200 %
Signal specifications
Sensing range Fx, Fy, Fz 100, 80, 80 N
Signal noise <0.8 N
Drift <1 N 72 hours
Sensitivity to temperature 25°C > T < 40°C Immune
Electrical specifications
Supply volatge DC 2.8-5.3 V
Communication interface USB
Acquisition Rate 60 Hz low noise