Fixture Fixture Accesses luminaire information such as serial number, software version, and
total operation hours. Also accesses recalibration and download options.
Green Green LED Specifies Green (intensity) parameter for manual control (Manual).
Int Level Intensity Level The Intensity Limiter is used to match overall output level of multiple VLX wash
luminaires if desired. The Intensity Limiter default is 100% and is adjustable by
the user. For example, if a fixture’s Intensity Limiter is set to’80’, a value of
100% from a desk will only output 80% of the fixture power (as determined by
the VLX Operation Mode - Normal, Quiet, Constant Fans or Level Light)
Inv Pan Invert Pan Reverses pan action for special focus requirements.
Inv Tilt Invert Tilt Reverses tilt action for special focus requirements.
LED Correction LED Calibration
Level
Sets LEDs to factory calibration level.
LED Fans LED Fan Test Specifies one of luminaire’s six fans for status (or current state) information.
LED Setup LED Operational
Settings
LED settings/operation of power level or calibration.
LED Status Current Status of
LED
Specifies one of luminaire’s seven LEDs for status (or current state) informa-
tion.
LED Temps LED Operational
Temperature
Measures temperature associated with LED operation - displays in degrees
Celsius
Level Light Fixture Mode Luminaire setup is in set to Level Light mode by user. This mode maintains a
reduced LED output to keep various fixtures from operating at different levels
depending upon thermal situations. The fans will run full speed, regardless of
junction temperatures.
Linear Dimming Curve -
Linear
Sets dimmer operation to standard linear dimming curve. See also, "Square
Law"
Manual Manual Accesses options for luminaire mechanism control by entry of data values.
Movement Movement Enables or disables pan and tilt movement.
Normal Fixture Mode (Default) Luminaire setup is in normal fan and LED operational mode. This
mode operates the luminaire’s fans according to the LED's junction tempera-
ture. Fans will vary in speed according to thermal readings by MCB.
OFF Off Turns off a function.
Off Time Display off time Shows the automatic shut-off time for the menu display.
OK Okay Indicates calibration has completed and no errors have occurred.
OK? Okay? Prompt for pressing [Enter] before an action is executed.
ON On Indefinitely Sets Menu Display to stay on until programmed otherwise (Display) or turns
on a function.
Pan Pan Specifies pan function for manual control (Manual) or testing (Test).
Pan/Tilt Pan/Tilt Accesses pan and tilt options for focus swap function, movement enable/dis-
able, manual control and testing.
PASS Test Pass Indicates that a test has passed.
Programming Luminaire soft-
ware program-
ming
The luminaire is in the process of being reprogrammed with a new version of
software.
Power Level Fixture operational
power level
Sets the output of the luminaire to Normal, Quiet (reduced fan operation and
light output), Constant Fans (fans stay at a constant speed, cooling capacity),
or Level (set operational level as desired by user)
Table 4-2: Menu Function Definitions (Continued)
Display Definition Purpose