VARILITE® - VLX™ WASH LUMINAIRE USERS MANUAL
50 15 April 2010 02.9690.0001 A
* For 16-bit parameters, the data displayed will be scaled to a range of 0-65535.
**Do NOT use or select RS232 unless instructed by Vari-Lite technical support to do so.
Test Fixture
operational
tests - Press
[ESC] to stop
tests
All Seq Selects fixture to run
and sequence through all
available tests
RUN TEST
Pan/Tilt Selects fixture to
run Pan/Tilt operational test
RUN TEST
Pan Selects fixture to run
Pan operational test
RUN TEST
Tilt Selects fixture to run Tilt
operational test
RUN TEST
Strobe Selects fixture to run
Strobe operational test
RUN TEST
LED Operational test of
each LED operation
RUN TEST
Beam Sprdr Selects fixture
to run beam spreader
mechanism operational test
RUN TEST
Int Level (Intensity Limiter)
Sets luminaire’s output to
the set percentage of the
operation mode setting.
This is used to match overall
output level of multiple
VLX™ wash luminaires if
desired.
XXX% (Enter value - up to 100%)
Set Maximum Output Value
LED Fans Selects and
displays fan speed for
1,2,3,4,6, or 7 (Note: LED 5
does not have a fan)
Fan X (select fan)
LED Temps Selects and
displays LED junction
temperature
LED Temp 1
thru LED Temp 7
LED Status Selects and
displays LED status
LED Status 1
thru LED Status 7
RS232 Log** Selects
RS232 logging operation
On
or Off** (SEE NOTE
BELOW)
Table 4-1: VLX Wash Menu System Chart
1st Level 2nd Level 3rd Level 4th Level 5thLevel