VARI❋LITE® is a trademark owned by Genlyte Thomas Group LLC and is registered in the United States and other countries. VL500™ (and the individual product designations), VL1000™, VL2000™, VL2201™, VL2202™, VL2400™ (and the individual product designations), VL2500™, VL3000™, VL3500™, Series 500™, Series 1000™, Series 2000™, Series 3000™, DICHRO❋TUNE™, VARI❋IMAGE™, and the Vari-Lite Asterisk are also trademarks owned by Genlyte Thomas Group LLC.
FOREWORD How To Obtain Warranty Service A copy of the Vari-Lite Limited Warranty was included in the shipping package for this VARI❋LITE® product. To obtain warranty service, please contact customer service at 1-877-VARI-LITE (1-877-827-4548), +1-214-647-7880, or customerservice@genlytecontrols.com and request a Return Material Authorization (RMA) for warranty service.
VARI❋LITE® - VL500™ WASH LUMINAIRE USER’S MANUAL Compliance Notice FCC This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when this equipment is operated in a commercial environment.
FOREWORD Safety Notice It is extremely important to read ALL safety information and instructions provided in this manual and any accompanying documentation before installing and operating the products described herein. Heed all cautions and warnings during installation and use of this product. Safety symbols used throughout this manual are as follows: CAUTION advising of potential damage to product. WARNING advising of potential injury or death to persons.
VARI❋LITE® - VL500™ WASH LUMINAIRE USER’S MANUAL WARNING: INSTRUCTIONS FOR CONTINUED PROTECTION AGAINST EXCESSIVE EXPOSURE TO UV RADIATION 1. Many VARI❋LITE® luminaires use a lamp that produces UV radiation. DO NOT look directly at lamp. 2. It is hazardous to operate luminaires without lens or shield. Shields, lenses, or ultraviolet screens shall be changed if they have become visibly damaged to such an extent that their effectiveness is impaired. For example, by cracks or deep scratches.
FOREWORD Sicherheitshinweise Es ist äußerst wichtig, ALLE Sicherheitsinformationen und -hinweise in diesem Handbuch und dem beiliegenden Informationsmaterial zu lesen, bevor Sie die hierin beschriebenen Produkte installieren bzw. bedienen. Halten Sie bei der Installation und dem Einsatz dieses Produkts alle Warnhinweise und Vorsichtsmaßnahmen ein. Folgende Sicherheitssymbole werden in diesem Handbuch verwendet: VORSICHT - weist auf möglichen Produktschaden hin.
VARI❋LITE® - VL500™ WASH LUMINAIRE USER’S MANUAL WARNUNG: HINWEISE ZUM SCHUTZ GEGEN ÜBERHÖHTE UV-STRAHLUNG 1. Viele VARI❋LITE®-Scheinwerfer verwenden die Lampentyp, der UV-Strahlen abgibt. SCHAUEN SIE NICHT direkt in die Lampe. 2. Es ist gefährlich, Leuchten ohne Linsen oder Blenden zu bedienen. Blenden, Linsen oder Ultraviolettschirme müssen ausgetauscht werden, sofern deren Schutzwirkung durch sichtbare Beschädigung (z. B. Sprünge oder Schrammen) eingeschränkt ist.
FOREWORD Notes de sécurité Avant de procéder à l’installation des produits décrits dans ce guide et de les mettre en marche, il est extrêmement important de lire TOUS les renseignements et TOUTES les directives de sécurité contenues dans ce guide ainsi que toute documentation jointe. Tenir compte de tous les avertissements et suivre toutes les précautions pendant l’installation et l’utilisation de cet appareil.
VARI❋LITE® - VL500™ WASH LUMINAIRE USER’S MANUAL AVERTISSEMENT: DIRECTIVES POUR SE PROTÉGER CONTRE UNE EXPOSITION EXCESSIVE AUX RAYONS UV 1. Plusieurs luminaires VARI❋LITE® utilisent une lampe qui produit des rayons UV. NE PAS fixer son regard sur la lampe. 2. L’utilisation des luminaires sans lentille ou blindage pose des risques.
FOREWORD Aviso sobre Seguridad Es muy importante leer TODA la información e instrucciones sobre seguridad que se indica en este manual así como en los documentos adjuntos antes de instalar y operar los productos descritos. Se debe prestar atención a todos los avisos y advertencias durante la instalación y uso de este producto. Los símbolos de seguridad usados en este manual son los siguientes: CUIDADO, indica posibles daños al producto. ADVERTENCIA, indica posibles lesiones o muerte a las personas.
VARI❋LITE® - VL500™ WASH LUMINAIRE USER’S MANUAL ADVERTENCIA: INSTRUCCIONES PARA PROTECCIÓN CONTINUA CONTRA LA EXPOSICIÓN EXCESIVA DE RADIACIÓN ULTRA VIOLETA 1. Muchas luminarias VARI❋LITE® usan un tipo de lámpara que produce radiación UV. NO mire directamente a la lámpara. 2. Es peligroso operar luminarias sin lentes o protectores. Debe cambiar los protectores, lentes o pantallas ultravioletas si se aprecia que han sido dañadas, y que su efectividad pudiera estar deteriorada.
FOREWORD 02.9 685.
VARI❋LITE® - VL500™ WASH LUMINAIRE USER’S MANUAL xii 01-March-2006 0 2.9685 .
TABLE OF CONTENTS Table of Contents Introduction About This Manual ...................................................................................................... Additional Documentation........................................................................................... Text Conventions ......................................................................................................... Customer Service .....................................................................................
VARI❋LITE® - VL500™ WASH LUMINAIRE USER’S MANUAL Luminaire Timing Luminaire Timing Channel Information .................................................................... Control Channel Functions ........................................................................................ Updating Software Reprogramming Luminaires ...................................................................................... Components Overview ..........................................................................
INTRODUCTION : ABOUT THIS MANUAL Introduction About This Manual This manual provides necessary information regarding safety, installation, operation and routine maintenance for VARI❋LITE® VL500™ Wash Luminaires. Familiarizing yourself with this information will help you to get the most out of your product. WARNING: It is important to read ALL accompanying safety and installation instructions to avoid damage to the product and potential injury to yourself or others.
VARI❋LITE® - VL500™ WASH LUMINAIRE USER’S MANUAL DMX512 is included.) USITT Inc. 6443 Ridings Road Syracuse, New York 13206-1111 USA Tel: (800) 938-7488 Fax: (866) 398-7488 / www.usitt.org Text Conventions The following styles and meanings are used throughout this manual: Style Meaning [Button] Front panel button. Example: Press [Menu]. [Up] / [Down] arrows Press either [Up] or [Down] arrow button at Menu Display. MENU LCD Menu Display read-out.
CHAPTER 1. Description This chapter contains descriptions of luminaire features and components, along with a list of accessories which are available. • Features • Components 02 .9685 .
VARI❋LITE® - VL500™ WASH LUMINAIRE USER’S MANUAL Features Overview Series 500TM Wash Luminaires feature highlights: • Color Mixing System: The patented DICRO❋TUNETM color mixing system using three sets of 16-radially mounted dichroic blades - magenta, blue, and amber - designed to produce smooth, full spectrum color cross-fades. The color system is available in standard and pastel colors. • Variable Beam Angle: •VL500: 12.5° to 20° (dependant upon lens type). •VL500D: 12.
DESCRIPTION : COMPONENTS 1 Components Included Items The following illustration shows all items included with the luminaire: VL500A Wash Models Neutrik PowerCon ® AC Input Connector Lamp (VL500 and VL500D models only) VL500A Wash Luminaires Warranty Card Unpack & Quick Start Guide External Arc Ballast Series 500 Wash CD ROM (User’s Manual) Ballast to Fixture Lamp Cable Product Registration Product Support Sheet VL500 and VL500D Wash Models Unconnectorized Lamp Power Cable (VL500 Only) IGBT Dimm
VARI❋LITE® - VL500™ WASH LUMINAIRE USER’S MANUAL Replacement Items/Accessories The following optional and/or replacement items can be ordered directly from your Authorized VARI❋LITE® Dealer or Vari-Lite. When ordering, please order by the Vari-Lite part number. 6 Vari-Lite Part No. Accessory 22.9620.0194 Safety Cable Assembly 25.9661.0057 DMX Termination Connector Assembly 28.9661.0054 Luminaire Programming (XLR5) Kit 42.9685.0201 Clear Lens (VNSP) 42.9685.
CHAPTER 2. Installation This chapter contains instructions for installation of the luminaire. It includes connecting power and data, along with instructions for powering up the luminaire for the first time and addressing it within your system. • Power and Data Cabling Requirements • Installation Procedures • Powering Up • Addressing • Transporting 02 .9685 .
VARI❋LITE® - VL500™ WASH LUMINAIRE USER’S MANUAL Power and Data Cabling Requirements Power The luminaire requires standard AC power distribution from 100-240 VAC, 50/60 Hz. Three amps to twelve amps will be required depending on the AC supply voltage and product model. Depending on the application, the luminaire’s AC input cable may require a different connector.
INSTALLATION : POWER AND DATA CABLING REQUIREMENTS 2 Current vs. Voltage The following tables provide the luminaire’s current draw at specific voltages. Total Luminaire Current is calculated with the lamp on and all motors sequencing. Table 2-1: VL500 Wash Luminaire - Current vs. Voltage (120V/1200W Lamp) Voltage @ 60Hz Total Luminaire Current (Motor + Lamp Current) Motor Current Lamp Current 90V 15.8A 2.5A 13.4A 100V 14.3A 2.3A 12.0A 110V 13.0A 2.1A 10.9A 120V 11.9A 1.9A 10.
VARI❋LITE® - VL500™ WASH LUMINAIRE USER’S MANUAL Voltage @ 60Hz Current 230V 5.4A 240V 5.2A Table 2-5: VL500A Wash Luminaire - Current vs. Voltage (575W Arc Lamp - Turbo Mode) Voltage @ 60Hz Current 90V 8.6A 100V 7.8A 110V 7.1A 120V 6.5A 130V 6.0A 140V 5.6A 180V 4.3A 190V 4.1A 200V 3.9A 210V 3.7A 220V 3.6A 230V 3.4A 240V 3.3A Table 2-6: VL500A Wash Luminaire - Current vs. Voltage (700W Arc Lamp - Normal Mode) 10 Voltage @ 60Hz Current 90V 9.5A 100V 8.5A 110V 7.
2 INSTALLATION : POWER AND DATA CABLING REQUIREMENTS Data Cables The luminaire is equipped with two, 5-pin XLR connectors for DATA IN and DATA THRU (out) applications. DATA IN requires a 5-pin, female XLR connector and DATA THRU requires a 5-pin, male XLR connector. When purchasing or constructing data cables, it is important that not only the correct cable type be used, but also quality cable to ensure a reliable DMX512 system.
VARI❋LITE® - VL500™ WASH LUMINAIRE USER’S MANUAL Recommended Cable Types/Manufacturers These are only a few of the suitable cable types. Any quality EIA485, twisted pair, 120 ohm, shielded cable will also work.
2 INSTALLATION : POWER AND DATA CABLING REQUIREMENTS Termination Connector A XLR termination connector is required at the last luminaire (or "far end of the line") to prevent signal reflections. Signal reflections may cancel out the signal at certain line lengths, resulting in errors. The terminator is also necessary for software downloads and running tests on multiple luminaires.
VARI❋LITE® - VL500™ WASH LUMINAIRE USER’S MANUAL Installation Procedures Installing Lamp In the event the lamp was packed separately during shipment, it will be necessary to install in the luminaire before use. WARNING: Ensure that power is removed from luminaire when installing lamp. CAUTION: Wear cotton gloves or other covering while installing lamp. Touching lamp glass with bare fingers will leave oil and may cause the lamp to explode or reduce lamp life.
INSTALLATION : INSTALLATION PROCEDURES 2 Hanging the Luminaire The VL500 wash luminaire can be hung horizontally or vertically from any structure designed to work with the type of load created by this moving luminaire. Two mounting truss hooks or other mounting hardware are required. Many compatible truss hooks are available from different manufacturers for your particular needs. A minimum of two hooks per luminaire is required.
VARI❋LITE® - VL500™ WASH LUMINAIRE USER’S MANUAL Installing in Truss: Step 1. Using two people, lift luminaire into mounting position. Step 2. Secure in place with truss hook. Ensure truss hook hardware that locks hook in place (e.g. wing bolt) is properly tightened and that luminaire is fully supported. Step 3. Attach safety cable (as required) as follows: Base (Foot) a. Connect end of cable to luminaire cable mounting hole on front of foot. b.
INSTALLATION : INSTALLATION PROCEDURES Step 2 4. Connect power and data cables according to procedure given in “Connecting Data and Power” on page 17. Figure 2-4: Hanging Dimensions and Clearances Floor Mounting the Luminaire VL500 wash luminaires are not designed nor sufficient to sit directly on its base (foot) in a floor installation application without a suitable floor mount plate.
VARI❋LITE® - VL500™ WASH LUMINAIRE USER’S MANUAL Step 3. At last luminaire in link, install male termination connector at DATA THRU connector. (Luminaires and other devices on the same DMX chain may not function properly without termination.) Data In from console AC In AC In AC In Data Thru Data Thru Termination Figure 2-5: Data Link 18 Step 4. Connect AC Input Cable connector to power input source. Step 5.
INSTALLATION : POWERING UP 2 Powering Up Power-Up Procedure All Models Since Lamp On is the default state, the lamp will come on (tungsten models) or strike (arc models) when the luminaire is powered up for the first time. When AC power is applied, the luminaire will immediately begin a calibration sequence that steps it through full pan and tilt movements. The internal color and beam mechanisms will also move through a full range of motion.
VARI❋LITE® - VL500™ WASH LUMINAIRE USER’S MANUAL Addressing Program Starting Address The address setting for DMX console controlled systems is entered using the Menu Display (refer to “Menu Operation” on page 42). The luminaire retains the DMX address even if power is removed. Note: Refer to your console operating instructions for specific information regarding its addressing requirements. Program a DMX starting address: Step 1. Press [Menu]. Step 2. Press [Up] / [Down] arrows until Address appears.
INSTALLATION : TRANSPORTING 2 Transporting Pack Up Cue When shipping or transporting a VL500 wash luminaire, certain settings should be used to minimize the possibility of damaging internal components. Because of the complexity and delicate nature of the 64 panes of dichroic glass filters used in the VL500 wash luminaire, extra care should be observed to minimize damage.
VARI❋LITE® - VL500™ WASH LUMINAIRE USER’S MANUAL Notes 22 01-March-2006 0 2.9685 .
CHAPTER 3. Operation This chapter contains instructions for operating the luminaire using DMX control and for updating the internal software. • Color Control • DMX Operation • DMX Mapping • Luminaire Timing • Updating Software 02 .9685 .
VARI❋LITE® - VL500™ WASH LUMINAIRE USER’S MANUAL Color Control The VL500 Wash Luminaire’s color system is composed of the patented DICRO❋TUNETM CYM, color mixing mechanism. The following sections describe the various components of the VL500 wash luminaire. CYM Crossfade Color Mixing The color mixing mechanism is made up of two individual color bulkheads that contain Cyan, Yellow, and Magenta (CYM).
3 OPERATION : DMX OPERATION DMX Operation VL500 Wash Channel Mapping These tables assume a DMX start address of 1. When a different starting address is used, this address becomes channel 1 function and other functions follow in sequence.
VARI❋LITE® - VL500™ WASH LUMINAIRE USER’S MANUAL DMX Mapping CYM Crossfade Color Mixing and Dimming CYM Crossfade Color Mixing Table 3-1: DMX Map For CYM Crossfade Color Mixing % Value DMX Value Action 0 0 Open (White) 100 255 Closed (Full Saturation) Dimming Table 3-2: DMX Map For Dimmer % Value DMX Value Action 0 0 Closed 100 255 Open Beam Control Beam (Diffuser) Table 3-3: DMX Map For Beam (Diffuser) - Tungsten Model Only % Value DMX Value Action 0 0 Narrowest (far focus)* 100 2
OPERATION : LUMINAIRE TIMING 3 Luminaire Timing Luminaire Timing Channel Information Timing channel control improves the timed moves of certain groups of parameters. Three timing channels are provided, one for Pan and Tilt, one for color parameters and one for beam parameters. Timing channels support time values of up to six minutes.
VARI❋LITE® - VL500™ WASH LUMINAIRE USER’S MANUAL Table 3-5: Timing Channels Map % Value 1 2 = Seconds 0 Full Speed 1 0.2 2 0.4 3 0.6 4 0.8 5 1 6 1.2 7 1.4 3 8 1.6 9 1.8 4 10 2 5 6 11 2.2 12 2.4 13 2.6 14 2.8 15 3 16 3.2 17 3.4 7 18 3.6 19 3.8 8 20 4 21 4.2 22 4.4 23 4.6 24 4.8 9 10 11 12 13 28 DMX 25 5 26 5.2 27 5.4 28 5.6 29 5.8 30 6 31 6.2 32 6.4 33 6.6 34 6.8 35 7.0 14 36 7.2 37 7.4 15 38 7.6 39 7.
OPERATION : LUMINAIRE TIMING 3 Table 3-5: Timing Channels Map (Continued) % Value DMX 40 8 16 41 8.2 42 8.4 17 43 8.6 44 8.8 45 9 46 9.2 47 9.4 48 9.6 49 9.8 50 10 51 10.2 52 10.4 53 10.6 54 11 18 19 20 21 22 55 11 56 12 57 12 58 13 23 59 13 60 14 24 61 14 62 14 63 15 64 15 65 16 66 16 67 16 68 17 27 69 17 70 18 28 71 18 72 18 25 26 29 30 31 02.9 685.
VARI❋LITE® - VL500™ WASH LUMINAIRE USER’S MANUAL Table 3-5: Timing Channels Map (Continued) % Value DMX = Seconds 32 82 22 83 23 84 23 85 23 86 24 34 87 24 88 25 35 89 25 90 25 33 36 37 26 92 26 93 27 94 27 95 27 96 28 97 28 98 29 99 29 100 29 101 30 102 30 103 30 104 31 41 105 31 106 32 42 107 32 108 32 38 39 40 43 44 45 46 47 48 30 91 109 33 110 33 111 34 112 34 113 34 114 35 115 35 116 36 117 36 118 36 119 37 120
OPERATION : LUMINAIRE TIMING 3 Table 3-5: Timing Channels Map (Continued) % Value DMX 124 39 49 125 39 126 39 50 51 52 53 54 55 127 40 128 40 129 41 130 41 131 41 132 42 133 42 134 43 135 43 136 43 137 44 138 44 139 45 140 45 141 45 142 46 56 143 46 144 47 57 145 47 146 47 147 48 148 48 149 49 150 49 151 49 152 50 153 50 154 50 155 51 156 51 58 59 60 61 62 02.9 685.
VARI❋LITE® - VL500™ WASH LUMINAIRE USER’S MANUAL Table 3-5: Timing Channels Map (Continued) % Value DMX = Seconds 65 166 55 167 56 168 56 169 56 170 57 67 171 57 172 58 68 173 58 174 58 66 69 59 176 59 177 59 178 60 70 179 60 180 65 71 181 65 182 65 183 70 184 70 185 75 186 75 187 75 188 80 74 189 80 190 85 75 191 85 192 85 72 73 76 77 78 79 80 81 32 175 193 90 194 90 195 95 196 95 197 95 198 100 199 100 200 110 201 110
OPERATION : LUMINAIRE TIMING 3 Table 3-5: Timing Channels Map (Continued) % Value DMX 208 140 82 209 140 210 140 83 84 85 86 87 88 89 90 91 92 93 94 95 02.9 685.
VARI❋LITE® - VL500™ WASH LUMINAIRE USER’S MANUAL Table 3-5: Timing Channels Map (Continued) % Value DMX = Seconds 98 250 300 251 310 252 310 253 310 254 310 255 Follows Cue Data 99 100 Control Channel Functions The following control actions must be accomplished with zero time transition or with timing disabled. Discrete values must be used and not manual controls such as faders or encoders.
OPERATION : UPDATING SOFTWARE 3 Updating Software Reprogramming Luminaires In some cases, it may be desirable to upgrade the luminaire’s operating software. This process requires a PC, VLDownload.exe, .bin files and the Luminaire Programming Kit (28.9661.0054). Components Overview Computer Requirements • PC running Windows 95/98, Windows NT (4.0 or higher), Windows 2000, or Windows XP. (Program is not compatible with Macintosh computers.) • Serial (DB9 connector) communication port.
VARI❋LITE® - VL500™ WASH LUMINAIRE USER’S MANUAL Reprogramming Procedure Note: Up to 32 luminaires can be programmed at the same time if they are data linked together. Refer to “Connecting Data and Power” on page 17. (Programming more than 32 luminaires will require programming in batches of 32 or less.) To update luminaire software: Step 1. From Product Downloads page at www.vari-lite.com, download and install the VLDownload.exe program and required .
OPERATION : UPDATING SOFTWARE 3 Note: Version dates shown in this graphic are for illustration purposes only and may not correspond to the version you are downloading. Click to download all listed software versions to connected luminaire(s) Click to download specific software version to connected luminaire(s) Lists the specific versions of software that have been downloaded Select PC serial port where cable is connected.
VARI❋LITE® - VL500™ WASH LUMINAIRE USER’S MANUAL Verify software version at luminaire: Step 1. At Menu Display, press [Menu]. Step 2. Press [Up] / [Down] arrows until Fixture appears. Press [Enter]. Step 3. Press [Up] / [Down] arrows until Version appears. Press [Enter]. The first half of the version date will be displayed as MM/DD/YY (month/day/year): For example, 07/21/02 = July 21, 2002 Press [Enter] to display second half of version date.
OPERATION : UPDATING SOFTWARE 3 Step 4. Press [Up] / [Down] arrows until Download appears. Press [Enter]. Step 5. OK? will be displayed. Press [Enter] to accept. Step 6. Download will proceed. (Download will take 4-5 seconds.) The number of blocks displayed will be less in a luminaire-to-luminaire download than in a PC-to-luminaire download for the same software version. Step 7. Once download is complete, luminaire will automatically recalibrate.
VARI❋LITE® - VL500™ WASH LUMINAIRE USER’S MANUAL Notes 40 01-March-2006 0 2.9685 .
CHAPTER 4. Menu System This chapter contains instructions for operating the luminaire using the Menu Display feature. • Menu Operation • Self Tests 02 .9685 .
VARI❋LITE® - VL500™ WASH LUMINAIRE USER’S MANUAL Menu Operation What Is the Menu System? The menu system is controlled by four buttons. These buttons function as follows: Series 500 Menu Display LCD Display Menu Display Softkeys - The menu has four softkey buttons that change to accommodate menu selection. Figure 4-1: Menu Display Location The menu offers four softkey button that change dynamically according to the menu selected at each level. To enter the menu system, first press [Menu].
MENU SYSTEM : MENU OPERATION 4 The menu system is a programmable set of commands used to configure, address, operate, and test the luminaire. The menu system is controlled at the Menu Display available at the enclosure input panel. The menu system has seven main functions which are referred to as “1st level.” Within these main functions, there can be up to four additional sub-functions (levels 2 thru 5), making five total levels. To enter the menu system, first press [Menu].
VARI❋LITE® - VL500™ WASH LUMINAIRE USER’S MANUAL Lamp Hours Progress Bar (Arc Models Only) For arc models, there is a Lamp Hours Progress Bar representing lamp hours used on the lamp. It is tied directly to the lamp hours within the MCB. The bar, when fully extended across the full width of the menu display, represents 750 lamp hours (as indicated in Figure 4-2). Resetting lamp hours will reset progress bar. This bar is only for a quick graphical representation of the lamp hours used.
4 MENU SYSTEM : MENU OPERATION Menu System Overview The following is a graphic representation of the entire menu system.
VARI❋LITE® - VL500™ WASH LUMINAIRE USER’S MANUAL Menu System Functions Table 4-1: Menu System Chart 1st Level 2nd Level Address DMX Address XXX Address value SetUp Luminaire Set Up Lamp Type 3rd Level Arc 4th Level 575W LAMP? / CNFIRM 575? 5thLevel Normal Turbo Lamp Saver 700W LAMP? / CNFIRM 700? Dimmer Normal Lamp Saver External External Dimmer 230V Internal Dimmer Voltage Setting (For use with the Internal 230V IGBT Dimmer Only) 120V Internal Dimmer Voltage Setting (For use with the Intern
MENU SYSTEM : MENU OPERATION 4 Table 4-1: Menu System Chart (Continued) 1st Level Configure System Configuration 2nd Level 3rd Level Power * Lamp Power Lamp Lamp Options * These lamp options are inactive (disabled) if external dimmer is selected in SetUp.
VARI❋LITE® - VL500™ WASH LUMINAIRE USER’S MANUAL Table 4-1: Menu System Chart (Continued) 1st Level DMX DMX Data and Pan/Tilt 2nd Level 3rd Level Mode 4th Level 5thLevel Extended Operates in extended 16 bit mode 16 Bit Operates in standard 16 bit mode 8 Bit Operates in 8 bit mode Easy Operates in a limited mode Data Chan XX DMX Channel XXXX Data Pan/Tilt Pan/Tilt Options Swap Swap Pan & Tilt ON OFF (default) InvPan Invert Pan ON OFF (default) InvTilt Invert Tilt ON OFF (default) Fixture M
MENU SYSTEM : MENU OPERATION 4 Table 4-1: Menu System Chart (Continued) 1st Level Test ** System Test 2nd Level 3rd Level ALL SEQ Sequence Through All Tests RunTest Pan/Tilt Pan/Tilt RunTest Pan Pan Pan 1 4th Level 5thLevel Press [Menu] to stop tests Pan 2 Tilt Tilt Tilt 1 Tilt 2 Dimmer Dimmer Dimmer 1 Dimmer 2 Dimmer 3 Diffuser Diffuser Diffuser 1 Diffuser 2 Diffuser 3 Cyan Cyan Color System Cyan 1 Cyan 2 Cyan 3 Yellow Yellow Color System Yellow 1 Yellow 2 Yellow 3 Magenta Magenta C
VARI❋LITE® - VL500™ WASH LUMINAIRE USER’S MANUAL Function Definitions Each menu item is listed in the first column by its display abbreviation. The abbreviations appear in alphabetical order as opposed to their position in the menu display sequence for easy reference. Table 4-2: Menu Function Definitions Display Definition Purpose 10Min 10 Minutes Sets Menu Display to automatically shut off after 10 minutes of non-use.
MENU SYSTEM : MENU OPERATION 4 Table 4-2: Menu Function Definitions (Continued) Display Definition Purpose DMX DMX Download Download Enable Enable Encoder Encoders External External Dimmer Fan Mode Fan Mode Sets the luminaires to operate normally (Auto -fans engage when preset thermal limits are surpassed) or off (Off). Fans Fan Speed Tests luminaire’s fan speed (0 = off to 7 = fastest). Accesses functions for setting DMX mode or pan/tilt options. Downloads program to luminaires.
VARI❋LITE® - VL500™ WASH LUMINAIRE USER’S MANUAL Table 4-2: Menu Function Definitions (Continued) 52 Display Definition ON On Indefinitely Pan/Tilt Pan/Tilt Pan Pan PASS Test Pass Power Lamp Power Power Up Lamp Power Up Re-cal Recalibrate Purpose Sets Menu Display to stay on until programmed otherwise (Display), turns on a function, or turns on a menu item. Accesses pan and tilt options for DMX function, system configuration, and testing.
MENU SYSTEM : SELF TESTS 4 Self Tests Running Parameter Tests The luminaire is capable of running self tests by using the TEST menu functions. For complete details and values for each test refer to “Diagnostic Tests” on page 54. When running tests on multiple luminaires, a DMX termination connector is required at the last luminaire in the link. (Refer to page 13 for more information regarding the construction of this connector.
VARI❋LITE® - VL500™ WASH LUMINAIRE USER’S MANUAL Movement Disable The Movement option allows pan and tilt to be disabled so that the luminaire can be placed in any position for testing without movement occurring. In order to regain full control of the luminaire, Movement will need to be enabled after testing. Note: When using the Movement option, pan and tilt will be disabled for all the luminaires that are linked. To set movement option: Step 1. Press [Menu]. Step 2.
APPENDIX A. Maintenance This appendix provides instructions for performing routine maintenance which may be necessary during the life of the luminaire. • Routine Maintenance WARNING: All maintenance procedures are to be performed with power removed from the luminaire. Never remove covers or open front lens or backcap assemblies while lamp is in operation. 02 .9685 .
VARI❋LITE® - VL500™ WASH LUMINAIRE USER’S MANUAL Routine Maintenance Lamp Replacement WARNING: Remove power from luminaire before performing maintenance. To remove and replace lamp: Step 1. Remove power from luminaire. WARNING: Lamps will be extremely HOT after operation. Allow lamp to cool before replacing. Step 2. Set the luminaire head horizontally. Step 3. Engage service tilt lock to secure luminaire head in position. Step 4. At backcap assembly, open latch and swing open back of luminaire.
TROUBLESHOOTING AND MAINTENANCE A Step 7. Install lamp by pressing firmly into socket. Ensure lamp is fully seated in socket with base of lamp against socket base. Step 8. Install lamp into lamp socket taking care not to touch lamp glass. Step 9. Close and re-latch back of luminaire. Step 10. Disengage service tilt lock to allow luminaire head to move freely. Step 11. If required, reset lamp hour counter as follows. (Refer to “Menu System Functions” chapter on page 46 for more information.) a.
VARI❋LITE® - VL500™ WASH LUMINAIRE USER’S MANUAL Front Glass Replacement WARNING: Remove power from luminaire before performing maintenance. Parts: as needed: GLASS, FRONT, CLEAR (Vari-Lite part: 42.9685.0201) GLASS, FRONT, STIPPLE (Vari-Lite part: 42.9685.0207) GLASS, FRONT, MED. FLOOD 8-ROW LENT. (Vari-Lite part: 42.9685.0203) GLASS, FRONT, MED. FLOOD 10-ROW LENT. (Vari-Lite part: 42.9685.0206) GLASS, FRONT, MED. FLOOD 12-ROW LENT. (Vari-Lite part: 42.9685.
TROUBLESHOOTING AND MAINTENANCE A WARNING: When installing a new or replacement lens in a VL500ATM (ARC) Wash, all lens types must be installed curve out (convex). In tungsten fixtures (VL500TM, VL500DTM, and VL500 80VTM Wash), Clear and Stipple lenses may be installed curve in (concave) and all Lenticular (8-Row, 10Row, and 12-Row) and Buxom lenses must be installed curve out (convex). Step 4. Position new glass in front ring assembly. Be sure glass is fully and properly seated. Step 5.
VARI❋LITE® - VL500™ WASH LUMINAIRE USER’S MANUAL Cleaning Optical Lenses and Filters WARNING: Remove power from luminaire before performing maintenance. The front lens, optics/color filters, and reflector may require cleaning after extended use. • FRONT LENS : Use a common glass cleaner along with a soft, lint-free cloth to clean the front lens. • OPTICS/COLOR FILTERS: Use Acetone or Isopropyl Alcohol along with a soft, lint-free cloth to clean the optics/color filters.
APPENDIX B. Technical Specifications Mechanical Color Enhanced DICHRO❋TUNETM radial color changing mechanism featuring independent blue, amber, and magenta color control capable of smooth, timed color crossfades or changes. Pastel (Dichroic Glass) Option: As an option, all versions of the VL500 wash luminaire are available with “pastel” or lighter colored blue and magenta color filters.
VARI❋LITE® - VL500™ WASH LUMINAIRE USER’S MANUAL Optical Source Model Lamp Color Temperature VL500 (120V) Tungsten, 120V, 1200W 3200oK VL500 (230V) Tungsten, 230V, 1000W 3200oK VL500D (120V) Tungsten, 120V, 1200W 3200oK VL500D (230V) Tungsten, 230V, 1000W 3200oK VL500A (575W) Arc, 575W 6000oK VL500A (700W) Arc, 700W 7200oK Reflector Precision glass reflector with dichroic cold mirror coating. Lens and Lens Options Factory lens is a stipple.
TECHNICAL SPECIFICATIONS B Operational Power Requirements Model Lamp Operating Voltage VL500 Tungsten, 120V, 1200W 90 - 120VAC, 50/60Hz Tungsten, 230V, 1000W 216 - 230VAC, 50/60Hz VL500D Tungsten, 120V, 1200W 90 - 120VAC, 50/60Hz Tungsten, 230V, 1000W 216 - 264VAC, 50/60Hz VL500 80V Tungsten, 80V, 1200W 90 - 264VAC, 50/60Hz VL500A Arc, 575W 90 - 264VAC, 50/60Hz VL500A Arc, 700W 90 - 264VAC, 50/60Hz Note: • Current draw depends on input voltage.
VARI❋LITE® - VL500™ WASH LUMINAIRE USER’S MANUAL Photometric 1200W, 120V Tungsten Lamp (3200K Color Temperature) Foot Candles Lux (cd) (measured at 124 inches) (measured at 3.149 meters) 7,241 352,139 3,300 6,933 164,545 1,542 Lens Lumens CANDELA Clear Stipple Beam Angle Field Angle (degrees) (degrees) 35,501 5.5 14.5 16,589 9.
B TECHNICAL SPECIFICATIONS Photometric (continued) 700W, Arc Lamp (7200K Color Temperature) Lens Lumens CANDELA Foot Candles Lux (cd) (measured at 124 inches) (measured at 3.149 meters) Clear 15,441 1,941,035 18,190 Stipple 14,402 694,467 6,510 02.9 685.00 01 0 01-March-2006 Beam Angle Field Angle (degrees) (degrees) 195,724 4 8 70,047 8 16.
VARI❋LITE® - VL500™ WASH LUMINAIRE USER’S MANUAL Notes 66 01-March-2006 0 2.9685 .
Vari-Lite 10911 Petal Street Dallas, Texas 75238 1-877-VARI-LITE 1-214-647-7880 www.vari-lite.com ©2006 Genlyte Group LLC. All rights reserved.