User`s manual
VARI❋LITE® - VL3000™ SERIES LUMINAIRE USER’S MANUAL
54 20-Aug-03 02.9678.0001 A
Troubleshooting
Error Messages
If a problem occurs during luminaire calibration, at the end of the calibration sequence the Menu
Display will cycle through any applicable error message(s) until the end of the list is reached. To
review the error messages again, it will be necessary to access them using the Status function.
To access error messages:
Step 1. Press [Menu].
Step 2. Press [Up] / [Down] arrows until Fixture appears. Press [Enter].
Step 3. Press [Up]/ [Down] arrows to access Status. Press [Enter]. (Display will now scroll
through any error messages or display OK if no errors.)
Table A-1: Error Messages
Display Message
OK No Errors Found
Pan/No Sens Pan sensor not found.
Pan/Encoder/Fail Pan encoder failure.
Tilt/No Sens Tilt sensor not found.
Tilt/Encoder/Fail Tilt encoder failure.
Index1/No Sens Gobo 1 Index sensor not found.
Gobo1/No Sens Rotating Gobo 1 sensor not found.
Index2/No Sens Gobo 2 Index sensor not found.
Gobo2/No Sens Rotating Gobo 2 sensor not found.
Index3/No Sens Gobo 3 Index sensor not found.
Gobo3/No Sens Rotating Gobo 3 sensor not found.
Dimmer/No Sens Dimmer sensor not found.
Blue/No Sens Blue sensor not found.
Amber/No Sens Amber sensor not found.
Magenta/No Sens Magenta sensor not found.
ColWheel/No Sens Color wheel sensor not found.
CTO/No Sens CTO sensor not found.
Zoom/No Sens Zoom sensor not found.
Edge/No Sens Edge sensor not found.