Power and Data Cabling Requirements
Power
The luminaire requires standard AC power distribution from 200-240 VAC, 50/60 Hz. Ten amps will
be required.
Depending on the application, the luminaire’s AC input cable may require a different connector. If
required, install a new connector meeting your requirements using the following wire color code:
* International (Harmonized) Standard
WARNING: DO NOT connect to three-phase Delta service in countries with 240 volt power.
Note: The lamp will not strike below 180 volts RMS.
For single-phase power at 200-240 volts RMS:
For three-phase power at 208 volts RMS:
Wire* Connection
Green/Yellow AC Ground
Blue AC Neutral
Brown AC Line
Connection Pin
AC Neutral X
AC Line Y
Ground (Earth) G
Connection Pin
Phase 1 X
Phase 2 Y
Ground (Earth) G
X
Y
G
X
Y
G