User`s manual
MENU SYSTEM : MENU OPERATION
4
02.9676.0019 A 05-January-2004 57
Gobo Gobo Select Specifies rotating gobo select for manual control (Man) or gobo select EOT sensor
for testing (
Test).
GobIndx Gobo Indexes Specifies rotating gobo select sensor for testing (Test).
Index Gobo Index Specifies rotating gobo index for manual control (Manual).
InvPan Invert Pan Reverses pan action for special focus requirements.
InvTilt Invert Tilt Reverses tilt action for special focus requirements.
Lamp Lamp Options For accessing lamp options and configuration (Config) or for testing (Test) to dis-
able pan/tilt for lamp adjustment.
Lamp
OFF
Lamp Off Configures arc luminaire to strike lamp on manual command.
Lamp ON Lamp On Configures arc luminaire to strike lamp at power up.
Lamp
Hour
Lamp Hours Displays total number of lamp operating hours.
LumId Luminaire ID Displays unique indentification number for the luminaire.
Magenta Magenta Color
Wheel
Specifies Magenta color wheel for manual control (Manual) or for testing (Test).
Manual Manual
Commands
Accesses functions for controlling luminaire mechanisms and timing by entry of an
absolute data value.
Model Model Displays type of luminaire (Spot or Wash).
Move-
ment
Movement Enables and disables pan and tilt movement and auto-correction.
NoProg No Program Indicates that there is no software present in the luminaire.
OFF Off Turns off a function.
OK Okay Indicates that luminaire is ready to accept commands.
OK? Okay? Prompt for pressing [Enter] before an action is executed.
ON On Indefinitely Sets Menu Display to stay on until programmed otherwise (Display), turns on a
function, or turns on a menu item.
Pan/Tilt Pan/Tilt Accesses pan and tilt options for DMX function, system configuration, and testing.
Pan Pan Specifies pan function for manual control (Manual) or pan encoder for testing (Test).
PASS Test Pass Indicates that sensor test has passed.
Power Lamp Power Accesses function to turn lamp on or off.
Power Up Lamp Power Up Accesses options for lamp power up: on, off, or after calibration.
Re-cal Recalibrate Recalibrates luminaire.
Reset Def Reset Default Resets default system configuration values.
Reset Hrs Reset Lamp Info Resets lamp hour and lamp strike counters. For use when new lamp is installed.
RotGobo Rotating Gobo For setting (Manual) or testing (Test) rotating gobo wheel or sensor.
RunTest Run Test Indicates that a system test is in progress.
Sensor Sensors Accesses sensor choices for diagnostic testing.
Sens Tst Sensor Test Indicates that a system sensor test is in progress.
SetUp Luminaire Set Up For selecting which (Model) of luminaire - spot or wash.
Spot Spot Luminaire Sets the software to work in a VL2500 Spot Luminaire.
Table 4-2: Menu Function Definitions (Continued)
Display Definition Purpose