Service manual
VARI❋LITE® - VL2500™ SPOT LUMINAIRE SERVICE MANUAL
36 29-May-2009 02.9676.0020 B
Ballast Module Assembly Replacement
Parts:
69.9676.0700
To remove and replace ballast module assembly:
Step 1. Disconnect luminaire AC input cable from power source.
Step 2. At enclosure, remove ballast-side and ventilation covers. Refer to
“Removing Enclosure Covers” on page 34.
Note: Throughout this procedure, please note different size screws and their respec-
tive locations
Step 3. Remove both handles by removing two 10-32 x 5/8" PPB screws at each.
Step 4. At enclosure, remove eight 6-32 x 3/8" PPZ screws and both side covers.
Figure 2-21.
Figure 2-21: Accessing Ballast Module
Step 5. At enclosure bottom, remove two 6-32x3/8" PPB screws, APS side bracket
and front cover from ballast side.
Front Cover
Side Cover (2)
Arc Ballast
Screws
Handle
Screws