Service manual

MAINTENANCE : MAINTENANCE PROCEDURES
2
02.9676.0020 B 29-May-2009 23
Rotating Gobo Sensor PCB Replacement
Parts:
24.9667.1321
To remove and replace rotating gobo sensor PCB:
Step 1. Disconnect luminaire AC input cable from power source.
Step 2. Remove front assembly. Refer to “Front Assembly Removal” on page 21.
Step 3. At rotating gobo wheel, remove two 4-40×3/8" PFZ screws (do not remove
middle screw) and remove wheel. Figure 2-7.
Figure 2-7: Rotating Gobo Wheel Removal
Center Screw
Do Not Remove
4-40×3/8”
PFZ Screws
Rotating Gobo Wheel
Rotating Gobo Sensor PCB