Service manual
VARI❋LITE® - VL2500™ SPOT LUMINAIRE SERVICE MANUAL
12 29-May-2009 02.9676.0020 B
Testing
Testing Software
Testing software is available in all Series 2000 luminaires through the luminaire’s
menu system TEST function.
For information on specific tests and test parameters, see the VL2500™ Spot
Luminaire User’s Manual (VL Part no. 02.9676.0019).
Note: After 10 seconds of inactivity, the menu display will change to the default state
showing the address.
Lamp
The Lamp option is available in the test menu. This option sets the lamp intensity to
100% and will adjust to produce a tight beam. Pan/Tilt are disabled while using the
Lamp option, and pan/tilt settings will be restored upon exit of the Lamp feature.
Note: When setting the Lamp option on luminaires linked by a five-wire DMX
cable, pan and tilt will be disabled for all the luminaires that are linked.
To run tests:
Step 1. Press [Menu].
Step 2. Press [Up] / [Down] arrows until TEST appears. Press [Enter].
Step 3. Use [Up] / [Down] arrows to select a parameter to test.
Step 4. Press [Enter] to run test.
Step 5. Press [Menu] to stop test at any time.