VARI❋LITE® is a trademark owned by Genlyte Thomas Group LLC and is registered in the United States and other countries. VL1000™, VL2000™, VL2201™, VL2202™, VL2400™ (and the individual product designations), VL3000™, Series 1000™, Series 2000™, Series 3000™, DICHRO❋TUNE™, VARI❋IMAGE™, and the Vari-Lite Asterisk are also trademarks owned by Genlyte Thomas Group LLC. VARI❋LITE® products are protected by one or more of the following patents, and other pending patent applications worldwide: U. S. Patents No.
FOREWORD How To Obtain Warranty Service A copy of the Vari-Lite Limited Warranty was included in the shipping package for this VARI❋LITE® product. To obtain warranty service, please contact customer service at 1-877-VARI-LITE (1-877-827-4548) or customerservice@vari-lite.com and request a Return Material Authorization (RMA) for warranty service.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Compliance Notice FCC This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when this equipment is operated in a commercial environment.
FOREWORD Safety Notice It is extremely important to read ALL safety information and instructions provided in this manual and any accompanying documentation before installing and operating the products described herein. Heed all cautions and warnings during installation and use of this product. Safety symbols used throughout this manual are as follows: CAUTION advising of potential damage to product. WARNING advising of potential injury or death to persons.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL WARNING: INSTRUCTIONS FOR CONTINUED PROTECTION AGAINST EXCESSIVE EXPOSURE TO UV RADIATION 1. Many VARI❋LITE® luminaires use a lamp that produces UV radiation. DO NOT look directly at lamp. 2. It is hazardous to operate luminaires without lens or shield. Shields, lenses, or ultraviolet screens shall be changed if they have become visibly damaged to such an extent that their effectiveness is impaired. For example, by cracks or deep scratches.
FOREWORD Sicherheitshinweise Es ist äußerst wichtig, ALLE Sicherheitsinformationen und -hinweise in diesem Handbuch und dem beiliegenden Informationsmaterial zu lesen, bevor Sie die hierin beschriebenen Produkte installieren bzw. bedienen. Halten Sie bei der Installation und dem Einsatz dieses Produkts alle Warnhinweise und Vorsichtsmaßnahmen ein. Folgende Sicherheitssymbole werden in diesem Handbuch verwendet: VORSICHT - weist auf möglichen Produktschaden hin.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL WARNUNG: HINWEISE ZUM SCHUTZ GEGEN ÜBERHÖHTE UV-STRAHLUNG 1. Viele VARI❋LITE®-Scheinwerfer verwenden die Lampentyp, der UV-Strahlen abgibt. SCHAUEN SIE NICHT direkt in die Lampe. 2. Es ist gefährlich, Leuchten ohne Linsen oder Blenden zu bedienen. Blenden, Linsen oder Ultraviolettschirme müssen ausgetauscht werden, sofern deren Schutzwirkung durch sichtbare Beschädigung (z. B. Sprünge oder Schrammen) eingeschränkt ist.
FOREWORD Notes de sécurité Avant de procéder à l’installation des produits décrits dans ce guide et de les mettre en marche, il est extrêmement important de lire TOUS les renseignements et TOUTES les directives de sécurité contenues dans ce guide ainsi que toute documentation jointe. Tenir compte de tous les avertissements et suivre toutes les précautions pendant l’installation et l’utilisation de cet appareil.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL AVERTISSEMENT: DIRECTIVES POUR SE PROTÉGER CONTRE UNE EXPOSITION EXCESSIVE AUX RAYONS UV 1. Plusieurs luminaires VARI❋LITE® utilisent une lampe qui produit des rayons UV. NE PAS fixer son regard sur la lampe. 2. L’utilisation des luminaires sans lentille ou blindage pose des risques.
FOREWORD Aviso sobre Seguridad Es muy importante leer TODA la información e instrucciones sobre seguridad que se indica en este manual así como en los documentos adjuntos antes de instalar y operar los productos descritos. Se debe prestar atención a todos los avisos y advertencias durante la instalación y uso de este producto. Los símbolos de seguridad usados en este manual son los siguientes: CUIDADO, indica posibles daños al producto. ADVERTENCIA, indica posibles lesiones o muerte a las personas.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL ADVERTENCIA: INSTRUCCIONES PARA PROTECCIÓN CONTINUA CONTRA LA EXPOSICIÓN EXCESIVA DE RADIACIÓN ULTRA VIOLETA 1. Muchas luminarias VARI❋LITE® usan un tipo de lámpara que produce radiación UV. NO mire directamente a la lámpara. 2. Es peligroso operar luminarias sin lentes o protectores. Debe cambiar los protectores, lentes o pantallas ultravioletas si se aprecia que han sido dañadas, y que su efectividad pudiera estar deteriorada.
FOREWORD 02.96 73.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL xii 02-May-03 02 .9 673 .
TABLE OF CONTENTS Table of Contents Introduction About This Manual ...................................................................................................... Additional Documentation........................................................................................... Text Conventions ......................................................................................................... Customer Service .....................................................................................
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Chapter 3. Operation Color/Gobo Control Color/Gobo Wheel Positions ..................................................................................... Standard Colors and Gobos........................................................................................ DMX Modes 8-Bit and 16-Bit Modes.............................................................................................. DMX Mapping Color and Gobo Control.................................
TABLE OF CONTENTS Appendix A. Troubleshooting and Maintenance Troubleshooting Error Messages........................................................................................................... Troubleshooting Guide............................................................................................... Routine Maintenance Lamp Replacement .................................................................................................... Color Filter Replacement ...............................
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Notes xvi 02-May-03 02 .9 673 .
INTRODUCTION : ABOUT THIS MANUAL Introduction About This Manual This manual provides necessary information regarding safety, installation, operation and routine maintenance for the VARI❋LITE® VL2000™ Spot Luminaire. Familiarizing yourself with this information will help you to get the most out of your product. WARNING: It is important to read ALL accompanying safety and installation instructions to avoid damage to the product and potential injury to yourself or others.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Text Conventions The following styles and meanings are used throughout this manual: Style Meaning [Button] Front panel button. Example: Press [Menu]. [Up] / [Down] arrows Press either [Up] or [Down] arrow button at Menu Display. MENU LCD Menu Display read-out. Example: Press [Up] / [Down] arrows until LAMP appears. Customer Service Our Goal At Vari-Lite, we are committed to providing you the highest quality in customer service.
CHAPTER 1. Description This chapter contains descriptions of luminaire features and components, along with a list of accessories which are available. • Features • Components 02.96 73.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Features Overview The VL2000 spot luminaire contains the following standard features: 4 • Variable beam focus to soften the edges of gobos or spots and enable gobo morphing. • Full field dimmer to allow smooth timed fades and fast blackouts. • A mechanical iris which provides continuous beam size control for both rapid beam size changes and smooth timed beam angle changes.
DESCRIPTION : COMPONENTS 1 Components Included Items The following illustration shows all items included with the luminaire: Quick Start Sheet Warranty Card User’s Manual VL2000 Spot Luminaire Mounting Brackets Figure 1-1: VL2000 Spot Luminaire Packing List Replacement Items/Accessories The following optional and/or replacement items can be ordered directly from Vari-Lite. (Please order by Vari-Lite part number.) 02.96 73.000 1 D Vari-Lite Part No. Accessory 20.9625.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL VL2000 Spot Luminaire The following illustration shows the major luminaire components and controls.
DESCRIPTION : COMPONENTS 1 LED Indicators The LED indicators report the status of power and data to the luminaire. Indicates DC power is being supplied via AC Input when lit Indicates data is being transmitted when flashing Indicates data is being received when flashing fast; when flashing in 2 sec. heartbeat, indicates luminaire is idle Figure 1-3: LED Indicator Overview 02.96 73.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Notes 8 02-May-03 02 .9 673 .
CHAPTER 2. Installation This chapter contains instructions for installation of the luminaire. It includes connecting power and data, along with instructions for powering up the luminaire for the first time and addressing it within your system. • Power and Data Cabling Requirements • Installation Procedures • Powering Up • Addressing 02.96 73.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Power and Data Cabling Requirements Power The luminaire requires standard AC power distribution from 100-240 VAC, 50/60 Hz. Three amps to twelve amps will be required depending on the AC supply voltage and product model. Depending on the application, the luminaire’s AC input cable may require a different connector.
INSTALLATION : POWER AND DATA CABLING REQUIREMENTS 2 Current vs. Voltage The following table provides the luminaire’s current draw at specific voltages. Current is calculated with the lamp on and all motors sequencing. Table 2-1: Current vs. Voltage Voltage @ 60Hz 02.96 73.000 1 D Current 90.0 11.8 100.0 10.6 110.0 9.5 120.0 8.5 130.0 7.9 140.0 7.2 180.0 5.5 190.0 5.2 200.0 4.9 210.0 4.7 220.0 4.5 230.0 4.3 240.0 4.1 250.0 3.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Data Cables The luminaire is equipped with two, 5-pin XLR connectors for DATA IN and DATA THRU (out) applications. DATA IN requires a 5-pin, female XLR connector and DATA THRU requires a 5-pin, male XLR connector. When purchasing or constructing data cables, it is important that not only the correct cable type be used, but also quality cable to ensure a reliable DMX512 system.
INSTALLATION : POWER AND DATA CABLING REQUIREMENTS 2 Recommended Cable Types/Manufacturers These are only a few of the suitable cable types. Any quality EIA485, twisted pair, 120 ohm, shielded cable will also work.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Male Termination Connector A male XLR termination connector is required at the last luminaire (or "far end of the line") to prevent signal reflections. Signal reflections may cancel out the signal at certain line lengths, resulting in errors. The terminator is also necessary for software downloads and running tests on multiple luminaires. To construct your own connector, you will need the following components: • 5-pin, male XLR connector.
INSTALLATION : INSTALLATION PROCEDURES 2 Installation Procedures Installing Lamp In the event the lamp was packed separately during shipment, it will be necessary to install in the luminaire before use. WARNING: Ensure that power is removed from luminaire when installing lamp. CAUTION: Wear cotton gloves or other covering while installing lamp. Touching lamp glass with bare fingers will leave oil and may cause the lamp to explode or reduce lamp life.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Hanging the Luminaire The VL2000 spot luminaire can be hung horizontally or vertically from any structure designed to work with the type of load created by this moving luminaire. Two mounting bracket assemblies (provided) are used to attach truss hooks or other mounting hardware as required. Many compatible truss hooks are available from different manufacturers for your particular needs. A minimum of one hook per truss hook bracket is required.
INSTALLATION : INSTALLATION PROCEDURES 2 Step 3. While pulling up on locking mechanism release, fit keyed holes onto raised mounting buttons at bottom of enclosure. Slide forward and release locking mechanism to lock in place. Ensure brackets are locked securely. (Always face brackets in same direction as shown.) WARNING: Ensure that the bracket locking mechanism is fully seated after the bracket is installed on the luminaire.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Installing in Truss: Step 1. Using two people, lift luminaire into mounting position. Step 2. Secure in place with truss hook. Ensure truss hook hardware that locks hook in place (e.g. wing bolt) is properly tightened and that luminaire is fully supported. Step 3. Attach safety cable (as required) as follows: a. Connect one end of cable to luminaire handle. b. Loop at least once around truss/pipe and attach other end of cable to other handle. Step 4.
INSTALLATION : INSTALLATION PROCEDURES 2 Floor Mounting the Luminaire The luminaire enclosure is sufficient to stabilize the luminaire in a floor installation, provided that the mounting surface is flat and sturdy. Connecting Data and Power A maximum of 32 luminaires may be connected in any one DMX data link. Note: This maximum limit applies to the luminaire "daisy chain" only. Your system or console may require fewer luminaires on a single data link path.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Powering Up Power-Up Procedure Since Lamp On is the default state, the lamp will strike when the luminaire is powered up for the first time. When AC power is applied, the luminaire will immediately begin a calibration sequence that steps it through full pan and tilt movements. The internal color, gobo, and beam mechanisms will also move through a full range of motion.
INSTALLATION : POWERING UP 2 Align Lamp for Flat Field The design of the VL2000 spot luminaire optical system is based on a flat field. A flat field is one where there is no detectable hot spot. After a new lamp is installed, it will be necessary to align the lamp to optimize the beam for the flat field. Knobs located at the luminaire’s backcap will allow adjustment. WARNING: Backcap and adjustment knobs will be HOT during lamp operation. Wear gloves and/or use tools to prevent burns.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Set DMX Mode The luminaire provide four modes for DMX operation. The mode is set using the Menu Display. • 8-bit Standard - provides one 8-bit DMX channel for control of each luminaire function. • 8-bit Enhanced - provides additional channels for timing control. • 16-bit Standard - provides 16-bit control for pan/tilt. • 16-bit Enhanced (default) - provides 16-bit control for pan/tilt and additional channels for timing control.
INSTALLATION : ADDRESSING 2 Addressing Program Starting Address The address setting for DMX console or Virtuoso console controlled systems is entered using the Menu Display. (Refer to “Menu System” chapter on page 47 for detailed instructions.) The luminaire retains the DMX and Virtuoso addresses that are stored even if power is removed. Note: Refer to your console operating instructions for specific information regarding its addressing requirements. Program a DMX or Virtuoso starting address: Step 1.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Notes 24 02-May-03 02 .9 673 .
CHAPTER 3. Operation This chapter contains instructions for operating the luminaire using DMX control and for updating the internal software. • Color/Gobo Control • DMX Modes • DMX Mapping • Luminaire Timing • Updating Software 02.96 73.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Color/Gobo Control Color/Gobo Wheel Positions The standard configurations for color and fixed gobo wheels are: all color filters installed on Wheel 1 (wheel nearest lamp) and all gobos installed on Wheel 2 (wheel nearer to front lens). These wheels each have 12 positions, one being open. Wheel 1 - Colors (Behind plate) Color/Gobo/Iris Bulkhead All rotating gobos are installed on the Rotating Gobo Wheel (nearest to front lens).
OPERATION : COLOR/GOBO CONTROL 3 Standard Gobos - Wheel 2 (Fixed Gobo Wheel) Pebbles Dust Breakup Medium Circles 4 3 Night Sky 5 6 2 7 1 8 12 11 Alpha Rays Leaves Liquid Breakup 9 10 Tribal Breakup Block Wave Breakup Vertical Bars Figure 3-3: Standard Gobos - Wheel 2 (Fixed Gobo Wheel) Standard Rotating Gobos open 5 Facet Prism Pinwheel 1 6 2 5 3 4 Circle of Ovals Spiral Stones Hypnospiral Figure 3-4: Standard Rotating Gobos 02.96 73.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL DMX Modes 8-Bit and 16-Bit Modes These tables assume a DMX start address of 1. When a different starting address is used, this address becomes channel 1 function and other functions follow in sequence.
OPERATION : DMX MAPPING 3 DMX Mapping Color and Gobo Control Color/Gobo Wheels Table 3-1: DMX Map For Color/Gobo Wheels % Value DMX (0-255) Wheel Position 0 0 Open Frame 1 1 2 1 3 2 5 4 6 7 3 8 9 4 Half Frame 10 11 12 5 13 6 15 14 16 17 7 18 8 20 Full Frame 2 19 21 22 9 23 24 10 25 26 Half Frame 27 11 28 29 30 12 31 32 13 02.96 73.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Table 3-1: DMX Map For Color/Gobo Wheels (Continued) % Value DMX (0-255) Wheel Position 34 35 14 36 Full Frame 3 37 15 38 39 40 16 41 42 17 43 44 Half Frame 45 18 46 19 48 47 49 50 20 51 52 53 21 54 Full Frame 4 55 22 56 57 58 23 59 60 24 61 62 Half Frame 63 25 64 26 66 65 67 68 27 69 70 28 71 72 Full Frame 5 73 29 74 75 30 02-May-03 02 .9 673 .
OPERATION : DMX MAPPING 3 Table 3-1: DMX Map For Color/Gobo Wheels (Continued) % Value DMX (0-255) 30 76 Wheel Position 77 78 31 79 80 Half Frame 81 32 82 33 84 83 85 86 34 87 88 35 89 90 Full Frame 6 91 36 92 37 94 38 97 93 96 98 39 Half Frame 99 100 101 40 102 103 104 41 105 42 107 106 108 Full Frame 7 109 43 110 44 112 111 113 114 45 115 116 46 Half Frame 117 118 02.96 73.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Table 3-1: DMX Map For Color/Gobo Wheels (Continued) % Value DMX (0-255) Wheel Position 119 47 120 121 48 122 123 124 49 125 126 Full Frame 8 127 50 128 51 130 129 131 132 52 133 134 53 Half Frame 135 136 137 54 138 139 55 140 141 142 56 143 57 145 144 Full Frame 9 146 147 58 148 149 59 150 151 152 60 Half Frame 153 154 155 61 156 157 62 158 159 160 32 02-May-03 02 .9 673 .
OPERATION : DMX MAPPING 3 Table 3-1: DMX Map For Color/Gobo Wheels (Continued) % Value DMX (0-255) 63 161 64 163 162 Wheel Position Full Frame 10 164 165 65 166 167 66 168 169 170 67 171 68 173 Half Frame 172 174 175 69 176 177 178 70 179 71 181 180 Full Frame 11 182 183 72 184 185 73 186 187 188 74 189 75 191 Half Frame 190 192 193 76 194 77 196 195 197 Full Frame 12 198 78 199 200 79 201 202 02.96 73.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Table 3-1: DMX Map For Color/Gobo Wheels (Continued) % Value DMX (0-255) Wheel Position 203 80 204 205 206 81 207 82 209 Half Frame 208 210 211 83 212 84 214 213 215 216 85 Spin F CCW 217 218 86 219 220 221 87 222 223 88 224 225 Spin M CCW 226 89 227 228 229 90 230 91 232 231 92 93 233 Spin S CCW 234 Stop 235 Stop 236 Stop 237 Spin S CW 238 239 94 240 241 95 242 243 244 34 02-May-03 02 .9 673 .
OPERATION : DMX MAPPING 3 Table 3-1: DMX Map For Color/Gobo Wheels (Continued) % Value DMX (0-255) 96 245 97 247 246 Wheel Position Spin M CW 248 249 98 250 251 99 252 253 254 100 255 Spin F CW Rotating Gobo Index/Rotation Table 3-2: DMX Map for Gobo Index/Rotation % Value DMX (0-255) Wheel Position 0-84 0-215 Index Position 85 216 Fast Spin CW 86-90 217-232 Variable Rates 91 233 Slow Spin CW 92 234-237 Stop 93 238 Slow Spin CCW 94-99 239-254 Variable Rates 100 255
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Beam Control Beam Iris Table 3-4: DMX Map For Beam Iris % Value DMX Value Action 0 0 Closed 100 255 Open Edge Table 3-5: DMX Map For Edge % Value DMX Value Action 0 0 Blooms In 100 255 Blooms Out Strobe Table 3-6: DMX Map For Strobe % Value DMX Value Action 0 0-2 Open 1 3-5 Closed 2 6-7 Slow Random 3 8-10 Med Random 4 11-12 Fast Random 5-100 13-255 Speed Range Zoom Table 3-7: DMX Map For Zoom 36 % Value DMX Value A
OPERATION : LUMINAIRE TIMING 3 Luminaire Timing Luminaire Timing Channel Information Timing channel control improves the timed moves of certain groups of parameters. We provide three timing channels, one for Focus (Pan and Tilt), one for color parameters and one for beam parameters. Timing channels support time values of up to six minutes.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Table 3-9: Timing Channels Map % Value DMX = Seconds 0 Full Speed 1 0.2 2 0.4 3 0.6 4 0.8 1 2 1 6 1.2 7 1.4 3 8 1.6 9 1.8 4 10 2 5 6 11 2.2 12 2.4 13 2.6 14 2.8 15 3 16 3.2 17 3.4 7 18 3.6 19 3.8 8 20 4 21 4.2 22 4.4 23 4.6 24 4.8 9 10 11 12 13 14 15 38 5 25 5 26 5.2 27 5.4 28 5.6 29 5.8 30 6 31 6.2 32 6.4 33 6.6 34 6.8 35 7.0 36 7.2 37 7.4 38 7.6 39 7.
OPERATION : LUMINAIRE TIMING 3 Table 3-9: Timing Channels Map (Continued) % Value 16 17 18 19 20 21 22 23 24 = Seconds 40 8 41 8.2 42 8.4 43 8.6 44 8.8 45 9 46 9.2 47 9.4 48 9.6 49 9.8 50 10 51 10.2 52 10.4 53 10.6 54 11 55 11 56 12 57 12 58 13 59 13 60 14 61 14 62 14 63 15 25 64 15 65 16 26 66 16 67 16 27 28 29 30 31 02.96 73.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Table 3-9: Timing Channels Map (Continued) % Value DMX = Seconds 32 82 22 83 23 33 84 23 85 23 34 35 36 24 24 88 25 89 25 90 25 91 26 92 26 93 27 94 27 95 27 96 28 38 97 28 98 29 39 99 29 100 29 37 40 41 42 43 101 30 102 30 103 30 104 31 105 31 106 32 107 32 108 32 109 33 110 33 111 34 112 34 113 34 114 35 45 115 35 116 36 46 117 36 118 36 44 47 48 40 86 87 119 37 12
OPERATION : LUMINAIRE TIMING 3 Table 3-9: Timing Channels Map (Continued) % Value 49 50 = Seconds 124 39 125 39 126 39 127 40 128 40 129 41 130 41 131 41 132 42 52 133 42 134 43 53 135 43 136 43 51 54 55 56 57 137 44 138 44 139 45 140 45 141 45 142 46 143 46 144 47 145 47 146 47 147 48 58 148 48 149 49 59 150 49 151 49 60 61 62 63 64 02.96 73.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Table 3-9: Timing Channels Map (Continued) % Value DMX = Seconds 65 166 55 167 56 66 168 56 169 56 67 68 69 70 71 57 57 172 58 173 58 174 58 175 59 176 59 177 59 178 60 179 60 180 65 181 65 182 65 183 70 72 184 70 185 75 73 186 75 187 75 74 75 76 77 188 80 189 80 190 85 191 85 192 85 193 90 194 90 195 95 196 95 197 95 198 100 78 199 100 200 110 79 201 110 202 110 80 81 42
OPERATION : LUMINAIRE TIMING 3 Table 3-9: Timing Channels Map (Continued) % Value 82 83 = Seconds 208 140 209 140 210 140 211 150 212 150 213 160 214 160 215 160 216 170 85 217 170 218 180 86 219 180 220 180 84 87 88 89 90 221 190 222 190 223 200 224 200 225 200 226 210 227 210 228 210 229 220 230 220 231 230 232 230 233 230 234 240 92 235 240 236 250 93 237 250 238 250 91 94 95 96 97 02.96 73.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Table 3-9: Timing Channels Map (Continued) % Value DMX = Seconds 98 250 300 251 310 99 252 310 253 310 100 254 310 255 Follows Cue Data Control Channel Functions The following control actions must be accomplished with zero time transition or with timing disabled. Discrete values must be used and not manual controls such as faders or encoders.
OPERATION : UPDATING SOFTWARE 3 Updating Software Reprogramming Luminaires In some cases, it may be desirable to upgrade the luminaire’s operating software. This process requires a PC, VLDownload.exe, .bin files and the Luminaire Programming Kit (28.9661.0054). Components Overview Computer Requirements • PC running Windows 95/98, Windows NT (4.0 or higher), or Windows 2000. (Program is not compatible with Macintosh computers.) • Serial communication port. (RS-232 only, USB not supported.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Reprogramming Procedure Note: Up to 32 luminaires can be programmed at the same time if they are data linked together. Refer to “Connecting Data and Power” on page 19. (Programming more than 32 luminaires will require programming in batches of 32 or less.) To update luminaire software: Step 1. From Product Downloads page at www.vari-lite.com, download and install the VLDownload.exe program and required .
OPERATION : UPDATING SOFTWARE 3 Note: Version dates shown in this graphic are for illustration purposes only and may not correspond to the version you are downloading. Click to download all listed software versions to connected luminaire(s) Click to download specific software version to connected luminaire(s) Lists the specific versions of software that have been downloaded Select PC serial port where cable is connected.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Verify software version at luminaire: Step 1. At Menu Display, press [Menu]. Step 2. Press [Up] / [Down] arrows until Fixt appears. Press [Enter]. Step 3. Press [Up] / [Down] arrows until Ver appears. Press [Enter]. The first half of the version date will be displayed as MM/DD/YY (month/day/year): For example, 07/21/02 = July 21, 2002 Press [Up] / [Down] arrows to display second half of version date.
OPERATION : UPDATING SOFTWARE 3 Step 3. At master luminaire Menu Display, press [Menu]. Step 4. Press [Up] / [Down] arrows until Fixture appears. Step 5. Press [Up] / [Down] arrows until Download appears. Press [Enter]. Step 6. OK? will be displayed. Press [Enter] to accept. Step 7. Download will proceed. (Download will take 1-2 seconds.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Notes 50 02-May-03 02 .9 673 .
CHAPTER 4. Menu System This chapter contains instructions for operating the luminaire using the Menu Display feature. • Operation • Display TestMapping • Cues and Sequences • Self Tests 02.96 73.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Operation What Is the Menu System? The menu system is a programmable set of commands used to configure, address, operate, and test the luminaire. The menu system is controlled at the Menu Display available at the enclosure input panel. Menu Display Figure 4-1: Menu Display Location The menu system has seven main functions which are referred to as “1st level.
MENU SYSTEM : OPERATION 4 To enter the menu system, first press [Menu]. The functions displayed will be 1st level functions. Scroll through the 1st level functions by pressing [Up] / [Down] arrows. Once the desired function appears in the display, press [Enter]. You are now at the 2nd level. Once again, press the [Up] / [Down] arrows to scroll through 2nd level functions. Press [Enter] to access 3rd level functions and so forth.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Default State The menu display’s default state during normal operation is to display the address (Virtuoso or DMX). After 10 seconds of inactivity at the display, it will change to the default state. After longer periods of inactivity, the menu display will switch to its off state. The default state for this feature is 5 minutes, however, different time lengths can also be programmed. To program a different time length for menu off feature: Step 1.
MENU SYSTEM : OPERATION 4 Shortcuts A few button combinations are provided as shortcuts for frequently used menu functions. These shortcuts are as follows: • Pressing [Enter] and [Up] at the same time = Lamp On • Pressing [Enter] and [Down] at the same time = Lamp Off • Pressing [Menu] and [Up] at the same time = Recalibrate • Pressing [Menu] at Power up interrupts calibration. See “Program Starting Address Without Calibrating the Luminaire” on page 23 for more information.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Menu System Overview The following is a graphic representation of the entire menu system.
MENU SYSTEM : OPERATION 4 Menu System Functions Table 4-1: Menu System Chart 1st Level Addr Address CFG System Configuration 2nd Level 3rd Level 4th Level DMX DMX Address XXX Address value VIRT Virtuoso Address XXXX.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Table 4-1: Menu System Chart (Continued) 1st Level Fixt Man Manual Commands 54 2nd Level 3rd Level 4th Level STAT Status/Error Display Scrolls error messages * or displays OK Cal Recalibrate OK? Modl Luminaire Model Type XXXX Model Type LId Luminaire ID XXXX. Luminaire ID Number (Page 1) XXXX Luminaire ID Number (Page 2) Ver Version XX.XX. Version (Page 1) XX.
MENU SYSTEM : OPERATION 4 Table 4-1: Menu System Chart (Continued) 1st Level Cue Cue Processing 2nd Level 3rd Level FLTM Follow Time XXX.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Table 4-1: Menu System Chart (Continued) 1st Level Test (cont.
MENU SYSTEM : OPERATION 4 Function Definitions Each menu item is listed in the first column by its display abbreviation. The abbreviations appear in alphabetical order as opposed to their position in the menu display sequence for easy reference. Table 4-2: Menu Fuction Definitions Display Definition 8 Standard 8-bit Configures luminaire for operation in standard DMX 8-bit mode. 16 Standard 16-bit Configures luminaire for operation in standard DMX 16-bit mode.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Table 4-2: Menu Fuction Definitions (Continued) 58 Display Definition Purpose DMX DMX Dnld Download DSEQ Delete Sequence Deletes cue sequence. E 16 Enhanced 16-bit Configures luminaire for operation in enhanced DMX 16-bit mode. E8 Enhanced 8-bit Configures luminaire for operation in enhanced DMX 8-bit mode. Edge/ EDGE Edge Motor Enab Enable Encr Encoders Accesses encoder choices for diagnostic testing.
MENU SYSTEM : OPERATION 4 Table 4-2: Menu Fuction Definitions (Continued) Display Definition Purpose MODE DMX Mode Accesses functions for setting DMX mode to standard or enhanced 8-bit or 16-bit. Modl Model Displays model number of luminaire. For example, 2413 (VL2413). Move Move Enables and disables pan and tilt movement and auto-correction. MSEQ Master Sequence NoPg No Program OFF Off OK Okay Indicates that luminaire is ready to accept commands.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Table 4-2: Menu Fuction Definitions (Continued) 60 Display Definition Purpose Tilt Tilt Time Timing Data Ver Version VIRT Virtuoso console Sets starting address for luminaire in Virtuoso systems. Whl1 Wheel 1 (Color) Specifies wheel 1 for manual control or testing. Whl2 Wheel 2 (Fixed Gobo) Specifies wheel 2 for manual control or testing. Zoom Zoom Specifies tilt function for manual control (Man) or tilt encoder for testing (Test).
MENU SYSTEM : CUES AND SEQUENCES 4 Cues and Sequences Overview The luminaire has the ability to store and playback cues independent of a console. Cues are stored as numbers from 1 to 99 by using the Cue (Cue Processing) functions available in the menu system. This also allows you to create your own test sequences to be played back on a group of luminaires. Refer to “Menu System Functions” on page 53 for a complete breakdown of Cue and Man (Manual Commands) functions.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Cue Operations The following section provides instructions for performing cue, sequence, and playback operations. Note: The Mod, Del, PCue, PSEQ commands will all display "---" if no cues have been stored. Note: After 10 seconds of inactivity at the display, it will change to the default state showing the address. To use the menus: The data stored by the luminaire is “last takes precedence.
MENU SYSTEM : CUES AND SEQUENCES 4 To store a cue: Step 1. Press [Menu]. Step 2. Press [Up] / [Down] arrows until Cue appears. Press [Enter]. Step 3. Press [Up] / [Down] arrows until Stor appears. Press [Enter]. The number displayed is the cue number to be stored. Step 4. Press [Enter] to store cue. (Number will increase by one for next cue to be stored.) Step 5. Repeat for remaining cues. To delete a cue: Step 1. Press [Menu]. Step 2. Press [Up] / [Down] arrows until Cue appears. Press [Enter]. Step 3.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL To change the follow time in a sequence: The follow time is stored for each cue individually. Step 1. Select cue to be changed from PCue. Step 2. Go to Mod to modify active cue and press [Enter] to save the change. Step 3. Set FLTM (Follow Time) to desired value (refer to “Set follow time between cues:” on page 62). To delete a sequence and all cues: Step 1. Press [Menu]. Step 2. Press [Up] / [Down] arrows until Cue appears. Press [Enter]. Step 3.
MENU SYSTEM : SELF TESTS 4 Self Tests Running Parameter Tests The luminaire is capable of running self tests by using the TEST menu functions. For complete details and values for each test refer to “Diagnostic Tests” on page 67. Note: After 10 seconds of inactivity, the menu display will change to the default state showing the address.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Movement Disable The Movement option allows pan and tilt to be disabled so that the luminaire can be placed in any position for testing without movement occurring. In order to regain full control of the luminaire, Movement will need to be enabled after testing. Note: When using the Movement option, pan and tilt will be disabled for all the luminaires that are linked. To set movement option: Step 1. Press [Menu]. Step 2.
MENU SYSTEM : SELF TESTS 4 Diagnostic Tests The following diagnostic tests are available in the test menu. Time is specified for each action in the test, and the total time equals the time it takes to complete each action. If the time is zero the luminaire will perform the test at full speed. Test Descriptions ALL1.................... Tests low voltage power supplies by moving all motors at once. ALL2.................... Tests all functions and provides a burn in or soak test. Cwl1 ....................
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Table 4-3: Diagnostic DMX Values Parameters Test Name ALL1 ALL2 68 Pan* Tilt* Dim CWh l F. Gob o Iris R.
4 MENU SYSTEM : SELF TESTS Table 4-3: Diagnostic DMX Values (Continued) Parameters Test Name ALL2 (cont.) PT 1 PT 2 Pan1 Pan2 02.96 73.000 1 D Pan* Tilt* Dim CWh l F. Gob o Iris R.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Table 4-3: Diagnostic DMX Values (Continued) Parameters Test Name Pan3 Tlt1 Tlt2 Tlt3 Dim1 Dim2 70 Pan* Tilt* Dim CWh l F. Gob o Iris R.
4 MENU SYSTEM : SELF TESTS Table 4-3: Diagnostic DMX Values (Continued) Parameters Test Name Dim3 Str 02.96 73.000 1 D Pan* Tilt* Dim CWh l F. Gob o Iris R. Gob o Inde x Edge Zoo m Str time/total time 45167 27000 255 0 0 0 0 0 0 0 0 0/0.5 45167 27000 128 0 0 0 0 0 0 0 0 0/0.5 45167 27000 80 0 0 0 0 0 0 0 0 0/0.5 45167 27000 100 0 0 0 0 0 0 0 0 0/0.5 45167 27000 40 0 0 0 0 0 0 0 0 0/0.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Table 4-3: Diagnostic DMX Values (Continued) Parameters Test Name Cwl1 Cwl2 Cwl3 72 Pan* Tilt* Dim CWh l F. Gob o Iris R.
4 MENU SYSTEM : SELF TESTS Table 4-3: Diagnostic DMX Values (Continued) Parameters Test Name FG 1 FG 2 FG 3 02.96 73.000 1 D Pan* Tilt* Dim CWh l F. Gob o Iris R.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Table 4-3: Diagnostic DMX Values (Continued) Parameters Test Name RG 1 RG 2 Irs1 Irs2 EDG1 EDG2 74 Pan* Tilt* Dim CWh l F. Gob o Iris R.
4 MENU SYSTEM : SELF TESTS Table 4-3: Diagnostic DMX Values (Continued) Parameters Test Name Zm 1 Zm 3 Pan* Tilt* Dim CWh l F. Gob o Iris R.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Notes 76 02-May-03 02 .9 673 .
APPENDIX A. Troubleshooting and Maintenance This appendix provides instructions for troubleshooting and performing routine maintenance which may be necessary during the life of the luminaire. • Troubleshooting • Routine Maintenance WARNING: All maintenance procedures are to be performed with power removed from the luminaire. Never open removable cover while lamp is in operation. 02.96 73.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Troubleshooting Error Messages If a problem occurs during luminaire calibration, at the end of the calibration sequence the Menu Display will cycle through any applicable error message(s), one a time until the end of the list is reached. To review the error messages again, it will be necessary to access them using the Status function. Refer to next page for a list of possible causes and remedies associated with the error messages.
TROUBLESHOOTING AND MAINTENANCE A Troubleshooting Guide If a problem is suspected, first try recalibrating the luminaire to prompt an error message. The chart below provides possible causes and remedies for various error messages and/or symptoms. CAUTION: Some troubleshooting is included for reference only. Performing remedies marked by gray areas will void product warranty. Refer to the Vari-Lite Limited Warranty card included with the product.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Table A-2: Troubleshooting Guide (Continued) Error Display Description B1M3 Whl1 NoSn Aux Board 1, Motor 3, Wheel 1, Sensor Not Found Possible Cause and Remedy Wheel 1 power not connected, motor not moving - Connect wheel 1 power at motor Wheel 1 sensor not connected - Connect wheel 1 sensor Wheel 1 movement restricted or impeded - Remove obstruction Wheel 1 sensor is faulty - Replace wheel 1 sensor assembly Aux Board 1 is faulty Replace aux board B1M3
TROUBLESHOOTING AND MAINTENANCE A Table A-2: Troubleshooting Guide (Continued) Error Display Description Possible Cause and Remedy BRD1 NO COMM Aux Board 1 Communication Failure Aux input connector (J5) not connected to either aux board - Connect aux input connector (J5) to either aux board Jumper/bridge connector (J1) between aux boards not connected - Install jumper/bridge connector (J1) between aux boards BRD2 NO COMM Aux Board 2 Communication Failure Aux input connector (J5) not connected to e
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Table A-2: Troubleshooting Guide (Continued) 82 Error Display Description Possible Cause and Remedy TILT NO SENS Tilt Sensor Not Found EOT flag attached to large pulley is not engaging the EOT sensor - Ensure flag is attached to the large pulley - Ensure that flag passes through the sensor at a depth sufficient to engage the sensor beam Tilt belt disconnected, extremely loose or not installed properly - Properly install belt between tilt motor and la
TROUBLESHOOTING AND MAINTENANCE A Routine Maintenance Lamp Replacement WARNING: Remove power from luminaire before performing maintenance. Tools: Screwdriver, slotted Cotton gloves To replace lamp: Step 1. Remove power from luminaire. WARNING: Lamps will be extremely HOT after operation. Allow lamp to cool before replacing. Step 2. At backcap, using slotted screwdriver (or fingers) turn captive knob until loose. Step 3.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL CAUTION: Wear cotton gloves or other covering while servicing lamp. Touching lamp glass with bare fingers will leave oil and may cause the lamp to explode or reduce lamp life. If required, use alcohol and cotton cloth to thoroughly clean glass portion of lamp. Step 4. Remove lamp by pulling straight out of socket. Step 5. Install new lamp by pressing into socket. Ensure lamp is fully seated in socket and parallel to guide rods.
TROUBLESHOOTING AND MAINTENANCE A Color Filter Replacement WARNING: Remove power from luminaire before performing maintenance. Tools: Screwdriver, Phillips #2 Cotton gloves To remove and replace a color filter: Step 1. Remove power from luminaire. Step 2. At removable cover, using #2 Phillips screwdriver, turn two captive screws one-quarter turn and remove cover. (It will remain attached by tether and lamp wires.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Note: In some cases it is easier to slide bulkhead partially out of head assembly to access color filters. To do this, use #2 Phillips screwdriver to turn captive screw one-quarter turn and slide bulkhead upward. Disconnect motor connections as necessary. Step 3. Rotate wheel until required color filter is accessible at finger access cutout. Finger Access Cutout Color Filter Figure A-3: Filter Access CAUTION: Do not touch color filters with bare fingers.
TROUBLESHOOTING AND MAINTENANCE A Fixed Gobo Replacement WARNING: Remove power from luminaire before performing maintenance. Tools: Screwdriver, Phillips #2 Cotton gloves To remove and replace a fixed wheel gobo: Step 1. Remove power from luminaire. Step 2. At removable cover, using #2 Phillips screwdriver, turn two captive screws one-quarter turn and remove cover. (It will remain attached by tether and lamp wires.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL CAUTION: Do not touch gobos with bare fingers. Wear cotton gloves or other covering while replacing. Clean with glass cleaner and soft cloth if required. Note: In some cases it is easier to slide bulkhead partially out of head assembly to access gobos. To do this, use #2 Phillips screwdriver to turn captive screw one-quarter turn and slide bulkhead upward. Disconnect motor connections as necessary. Step 3.
TROUBLESHOOTING AND MAINTENANCE A Rotating Gobo Replacement WARNING: Remove power from luminaire before performing maintenance. Tools: Screwdriver, Phillips #2 Hook and Pick tool (or small slotted screwdriver) Cotton gloves To remove and replace a rotating gobo: Step 1. Remove power from luminaire. Step 2. At removable cover, using #2 Phillips screwdriver, turn two captive screws one-quarter turn and remove cover. (It will remain attached by tether and lamp wires.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Step 3. At rotating gobo wheel, rotate until required gobo/filter is accessible. Step 4. Locate end of coiled spring which is fitted under carrier tab. Using hook and pick tool or small slotted screwdriver, push end of spring from under tab until it is free. Once free, remove entire coiled spring.
TROUBLESHOOTING AND MAINTENANCE A Cleaning Optical Lenses and Filters WARNING: Remove power from luminaire before performing maintenance. The front lens, color filters, and gobos may require cleaning after extended use. A common glass cleaner can be used along with a soft, lint-free cloth to clean these components. CAUTION: Do not continuously rub filters or it may damage or remove the optical coating. 02.96 73.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Notes 92 02-May-03 02 .9 673 .
APPENDIX B. Technical Specifications Mechanical Intensity Control Full-field dimming designed for both smooth timed fades and strobe effects. Color/Fixed Gobo Wheels Two, 12-position wheels, each providing 11 easily loaded positions (and 1 open) for userselectable color and gobo choices. Rotating Gobo Wheel Six-position rotating gobo wheel with five rotatable, indexable gobo positions and one open position. Zoom Optics Zoom angle of 2.8 to one. Continuously variable field angle from 19° to 43°.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Optical Source 700 Watt Short-Arc Lamp, 5600°K, 80CRI Reflector Precision glass reflector with dichroic cold mirror coating. Flat field design. Operational Power Requirements All VL2000 models are powered through standard AC power distribution and require three amps to twelve amps depending on the AC supply voltage and product model.
----------------------------------------------------------------------------------------------------------------- Returning Parts for Service Obtaining RMA Number and Returning Parts 1. Contact Service Center. 2. Request Return Material Authorization (RMA) number. 3. Do not remove glass color discs from luminaire subassemblies. 4. Package all parts being shipped. Please take great care in packing your items.