Power and Data Cabling Requirements
AC Power
WARNING: Do not power a VL1100CD ERS Luminaire from a dimmed circuit - even in "Non-
Dim" mode. Dimmer and non-dim modules are not suitable sources of power because their output
modifies the AC wave form. This may work for a short time, but will eventually result in power
problems, luminaire mis-operation and/or failure. Using a dimmer or non-dim module to power your
VA RI❋LITE luminaire will void your luminaire’s warranty.
The luminaire requires standard AC power distribution from 90-264 VAC, 50/60 Hz in order to power
all internal electronics and motors. It is equipped with a 3-pole Neutrik® PowerCon® locking
connector (with contacts for line, neutral, and premating safety grounds) for the purpose of AC input.
The mating Neutrik PowerCon® connector is supplied, however, you will need to purchase or
construct a cable appropriate for your application.
* International (Harmonized) Standard
Figure 2-1: Power Connector
Current vs. Voltage
The following tables provide the luminaire’s current draw at specific voltages. (Currents given are
worst case with all motors sequencing.)
Wire* Connection
Green/Yellow AC Ground
Blue AC Neutral
Brown AC Line
3-Pole Neutrik
Locking Connector
for AC input
Neutrik PowerCon
Connector (supplied)
VL1100CD
Input Panel
Table 2-1: VL1100CD Current vs. Voltage (Total Fixture Power)
Voltage @ 60Hz Current
100 6.0 A
240 3.0 A