VARI❋LITE® - VL1000™ ERS LUMINAIRE USER’S MANUAL
68 05-Oct-2007 02.9663.0001 G
Troubleshooting
Error Messages
If a problem occurs during luminaire calibration, at the end of the calibration sequence the Menu
Display will cycle through any applicable error message(s) until the end of the list is reached. To
review the error messages again, it will be necessary to access them using the Status function.
To access error messages:
Step 1. Press [Menu].
Step 2. Press [Up] / [Down] arrows until Fixture appears. Press [Enter].
Step 3. Press [Up]/ [Down] arrows to access Status. Press [Enter]. (Display will now scroll
through any error messages or display OK if no errors.)
Table A-1: Error Messages
Display Message...
OK No Errors Found
Pan/No Sens Pan sensor not found.
Pan/Encoder/Fail Pan encoder failure.
Tilt/No Sens Tilt sensor not found.
Tilt/Encoder/Fail Tilt encoder failure.
Index/No Sens Gobo Index sensor not found.
Rot Gobo/No Sens Rotating Gobo sensor not found.
Lamp/Strike/Fail Lamp strike failure.