User`s manual
VARI❋LITE® - VL1000™ ERS LUMINAIRE USER’S MANUAL
36 25-Feb-02 02.9663.0001
Step 4. Set console timing (or cue fade time) for parameters and timing channels to
zero seconds.
Step 5. Store cue.
Note: Avoid changing timing channel values in a fading cue. This can cause
unexpected behavior in the luminaire as the timing channel value is updated over time.
Timing channel values and the final destination of the parameters affected by the
timing channel should always be sent in a zero count.
Timing channels can be set in either % or 0-255 (DMX) modes, with the following
values assigned:
Table 3-10: Timing Channels Map
% Value DMX = Seconds
0 Full Speed
10.2
20.4
130.6
40.8
251
61.2
71.4
381.6
91.8
4102
11 2.2
12 2.4
5132.6
14 2.8
6153
16 3.2
17 3.4
7183.6
19 3.8
8204
21 4.2
22 4.4
9234.6
24 4.8
10 25 5