User`s manual
MENU SYSTEM : CUES AND SEQUENCES
4
02.9673.0001 C 17-Sep-02 69
To play cues as a sequence:
Step 1. Press [Menu].
Step 2. Press [Up] / [Down] arrows until Cue appears. Press [Enter].
Step 3. Press [Up] / [Down] arrows until PSEQ appears. Press [Enter] and the
sequence will play. The active cue will be shown in the display. [Enter] to
start, [Menu] to stop.
To change the follow time in a sequence:
The follow time is stored for each cue individually.
Step 1. Select cue to be changed from PCue.
Step 2. Go to Mod to modify active cue and press [Enter] to save the change.
Step 3. Set FLTM (Follow Time) to desired value (refer to “Set follow time between
cues:” on page 67).
To delete a sequence and all cues:
Step 1. Press [Menu].
Step 2. Press [Up] / [Down] arrows until Cue appears. Press [Enter].
Step 3. Press [Up] / [Down] arrows until DSEQ appears. Press [Enter].
Step 4. OK? prompt will appear. Press [Enter] to delete stored sequence.
Choose Sequence Mode:
MSEQ will replay the cues from the master luminaire.
ISEQ will play the cues from each individual luminaire, if any. In ISEQ, if the
number of cues is different, it will only play as many as each luminaire has stored.
The follow time is taken from the master luminaire.
Step 1. Press [Menu].
Step 2. Press [Up] / [Down] arrows until Cue appears. Press [Enter].
Step 3. Press [Up] / [Down] arrows until SEQ appears. Press [Enter].
Step 4. Press [Up] / [Down] arrows to toggle between ISEQ and MSEQ. Press
[Enter] to select mode.
To make a sequence AutoPlay at power up:
Step 1. Press [Menu].
Step 2. Press [Up] / [Down] arrows until Cue appears. Press [Enter].
Step 3. Press [Up] / [Down] arrows until Auto appears. Press [Enter].
Step 4. Use [Up] / [Down] arrows to toggle between OFF (the default) and ON.
Press [Enter] to select the mode.