User`s manual

VARILITE® - VL2000™ SPOT LUMINAIRE USERS MANUAL
58 17-Sep-02 02.9673.0001 C
Menu System Functions
Table 4-2: Menu System Functions
1st Level 2nd Level 3rd Level 4th Level 5thLevel
Addr
Address
DMX DMX Address XXX Address value
VIRT Virtuoso Address XXXX. Address value
CFG
System
Configuration
LAMP Lamp Options POWR Lamp Power ON (default)
OFF
P UP Lamp Power-up State L ON Lamp On
(default)
LOFF Lamp Off
C ON On after
Calibration
LHrs Lamp Hours Used XXXX Cumulative #
of Operation Hours
(Not editable)
Strk # of Lamp Strikes XXXX # of Strikes
(not editable)
RHrs Reset Lamp Hour
and Lamp Strike Counters
OK?
P/T Pan and Tilt Options Move Position Recovery Enab Enable
Dis Disable
DDir Display Orientation Auto (default)
⇓⇓
⇑⇑
DisP Display Illumination 30s OFF in 30 seconds
5M OFF in 5 minutes
(default)
10M OFF in 10 minutes
ON ON indefinitely
RDef Reset Default Values OK?
DMX
DMX Mode
and Data
MODE 8 Standard 8 bit
16 Standard 16 bit (default)
E 8 Enhanced 8 bit
E16 Enhanced 16 bit
DATA cXXX DMX Channel XXXX Data
P/T Pan/Tilt Options SWAP Swap Pan & Tilt ON
OFF (default)
InvP Invert Pan ON
OFF (default)
InvT Invert Tilt ON
OFF (default)