User`s manual
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL
56 17-Sep-02 02.9673.0001 C
Error Messages
If a problem occurs during luminaire calibration, at the end of the calibration sequence
the Menu Display will cycle through any applicable error message(s), one a time until
the end of the list is reached. To review the error messages again, it will be necessary
to access them using the Status function. (Refer to “Troubleshooting” on page 84 for a
list of possible causes and remedies associated with the error messages.)
To access error messages:
Step 1. Press [Menu].
Step 2. Press [Up] / [Down] arrows until Fixt (Fixture) appears. Press [Enter].
Step 3. Press [Up]/ [Down] arrows to access STAT. Press [Enter]. (Display will
now scroll through any error messages or display OK if no errors.)
Table 4-1: Error Messages
Display Message...
OK No Errors Found
B1M1 / Whl2 / NoSn Aux Board 1, Motor 1 / Wheel 2 / Sensor Not Found
B1M1 / Whl2 / SAct Aux Board 1, Motor 1 / Wheel 2 / Sensor Always Active
B1M2 / Dimm / NoSn Aux Board 1, Motor 2 / Dimmer / Sensor Not Found
B1M2 / Dimm / SAct Aux Board 1, Motor 2 / Dimmer / Sensor Always Active
B1M3 / Whl1 / NoSn Aux Board 1, Motor 3 / Wheel 1 / Sensor Not Found
B1M3 / Whl1 / SAct Aux Board 1, Motor 3 / Wheel 1 / Sensor Always Active
B2M1 / Gobo / NoSn Aux Board 2, Motor 1 / Rotating Gobo Wheel / Sensor Not Found
B2M1 / Gobo / SAct Aux Board 2, Motor 1 / Rotating Gobo Wheel / Sensor Always
Active
B2M2 / Indx / NoSn Aux Board 2, Motor 2 / Rotating Gobo Index / Sensor Not Found
B2M2 / Indx / SAct Aux Board 2, Motor 2 / Rotating Gobo Index / Sensor Always
Active
BRD1 / NO / COMM Aux Board 1 Communication Failure
BRD2 / NO / COMM Aux Board 2 Communication Failure
LAMP / STRK / FAIL Lamp Strike Failure
PAN / ENCR / FAIL Pan Encoder Failure
PAN / NO / SENS Pan Sensor Not Found
PAN / SENS / ACTV Pan Sensor Always Active
SRCH/FOR/BRD1 Attempting to communicate with Board 1
SRCH/FOR/BRD2 Attempting to communicate with Board 2
TILT / ENCR / FAIL Tilt Encoder Failure
TILT / NO / SENS Tilt Sensor Not Found
TILT / SENS / ACTV Tilt Sensor Always Active
WAIT Retrieving Current Status
WRNG / SW / PROG Wrong Software Program