B2M2
Indx
SAct
Aux Board 2, Motor 2,
Rotating Gobo Index,
Sensor Always Active
Rotating gobo index power not
connected, rotating gobo wheel
power not connected and both
wheel and index aligned with sensor
- Connect rotating gobo wheel and
index power at motors
BRD1
NO
COMM
Aux Board 1
Communication Failure
Aux input connector (J5) not
connected to either aux board
- Connect aux input connector (J5)
to either aux board
Jumper/bridge connector (J1)
between aux boards not connected
- Install jumper/bridge connector
(J1) between aux boards
BRD2
NO
COMM
Aux Board 2
Communication Failure
Aux input connector (J5) not
connected to either aux board
- Connect aux input connector (J5)
to either aux board
Jumper/bridge connector (J1)
between aux boards not connected
- Install jumper/bridge connector
(J1) between aux boards
LAMP
STRK
FAIL
Lamp Strike Failure Lamp failed to strike after repeated
attempts
- Replace lamp
PAN
ENCR
FAIL
Pan Encoder Failure Main board pan/tilt connector (J9)
disconnected
- Connect main board pan/tilt
connector (J9)
Pan motor disconnected
- Connect pan motor power
Encoder faulty
Replace pan end-of-travel/encoder
sensor assembly
PAN
NO
SENS
Pan Sensor Not Found EOT flag attached to large pulley is
not engaging the EOT sensor
- Ensure flag is attached to the
large pulley
- Ensure that flag passes through
the sensor at a depth sufficient
to engage the sensor beam
Pan belt disconnected, extremely
loose or not installed properly
- Properly install belt between pan
motor and large pulley
Table A-1: Troubleshooting Guide (Continued)
Error Display Description Possible Cause and Remedy