M a n u a l VL2000™ Spot Luminaire U s e r ’ s 02.9673.
VARI❋LITE - VL2000™ SPOT LUMINAIRE USER’S MANUAL VARI❋LITE®, Artisan®, VL2®, and VLD® are trademarks owned by Vari-Lite, Inc., 201 Regal Row, Dallas TX 75247 USA. and are registered in the United States and other countries.
HOW TO OBTAIN WARRANTY SERVICE How To Obtain Warranty Service A copy of the Vari-Lite, Inc. Limited Warranty was included in the shipping package for this VARI❋LITE® product. To obtain warranty service, please contact customer service at 1-877-VARI-LITE (1-877-827-4548) or customerservice@vlint.com and request a Return Material Authorization (RMA) for warranty service.
VARI❋LITE - VL2000™ SPOT LUMINAIRE USER’S MANUAL Compliance Notice FCC This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when this equipment is operated in a commercial environment.
SAFETY NOTICE Safety Notice It is extremely important to read ALL safety information and instructions provided in this manual and any accompanying documentation before installing and operating the products described herein. Heed all cautions and warnings during installation and use of this product. Safety symbols used throughout this manual are as follows: CAUTION advising of potential damage to product. WARNING advising of potential injury or death to persons.
VARI❋LITE - VL2000™ SPOT LUMINAIRE USER’S MANUAL WARNING: INSTRUCTIONS FOR CONTINUED PROTECTION AGAINST EXCESSIVE EXPOSURE TO UV RADIATION 1. Many VARI❋LITE® luminaires use an HID type lamp that produces UV radiation. DO NOT look directly at lamp. 2. It is hazardous to operate luminaires without lens or shield. Shields, lenses, or ultraviolet screens shall be changed if they have become visibly damaged to such an extent that their effectiveness is impaired. For example, by cracks or deep scratches.
SICHERHEITSHINWEISE Sicherheitshinweise Es ist äußerst wichtig, ALLE Sicherheitsinformationen und -hinweise in diesem Handbuch und dem beiliegenden Informationsmaterial zu lesen, bevor Sie die hierin beschriebenen Produkte installieren bzw. bedienen. Halten Sie bei der Installation und dem Einsatz dieses Produkts alle Warnhinweise und Vorsichtsmaßnahmen ein. Folgende Sicherheitssymbole werden in diesem Handbuch verwendet: VORSICHT - weist auf möglichen Produktschaden hin.
VARI❋LITE - VL2000™ SPOT LUMINAIRE USER’S MANUAL WARNUNG: HINWEISE ZUM SCHUTZ GEGEN ÜBERHÖHTE UV-STRAHLUNG 1. Viele VARI❋LITE®-Scheinwerfer verwenden einen HID-Lampentyp, der UV-Strahlen abgibt. SCHAUEN SIE NICHT direkt in die Lampe. 2. Es ist gefährlich, Leuchten ohne Linsen oder Blenden zu bedienen. Blenden, Linsen oder Ultraviolettschirme müssen ausgetauscht werden, sofern deren Schutzwirkung durch sichtbare Beschädigung (z. B. Sprünge oder Schrammen) eingeschränkt ist.
NOTES DE SÉCURITÉ Notes de sécurité Avant de procéder à l’installation des produits décrits dans ce guide et de les mettre en marche, il est extrêmement important de lire TOUS les renseignements et TOUTES les directives de sécurité contenues dans ce guide ainsi que toute documentation jointe. Tenir compte de tous les avertissements et suivre toutes les précautions pendant l’installation et l’utilisation de cet appareil.
VARI❋LITE - VL2000™ SPOT LUMINAIRE USER’S MANUAL AVERTISSEMENT: DIRECTIVES POUR SE PROTÉGER CONTRE UNE EXPOSITION EXCESSIVE AUX RAYONS UV 1. Plusieurs luminaires VARI❋LITE® utilisent une lampe de type HID qui produit des rayons UV. NE PAS fixer son regard sur la lampe. 2. L’utilisation des luminaires sans lentille ou blindage pose des risques.
AVISO SOBRE SEGURIDAD Aviso sobre Seguridad Es muy importante leer TODA la información e instrucciones sobre seguridad que se indica en este manual así como en los documentos adjuntos antes de instalar y operar los productos descritos. Se debe prestar atención a todos los avisos y advertencias durante la instalación y uso de este producto. Los símbolos de seguridad usados en este manual son los siguientes: CUIDADO, indica posibles daños al producto.
VARI❋LITE - VL2000™ SPOT LUMINAIRE USER’S MANUAL ADVERTENCIA: INSTRUCCIONES PARA PROTECCIÓN CONTINUA CONTRA LA EXPOSICIÓN EXCESIVA DE RADIACIÓN ULTRA VIOLETA 1. Muchas luminarias VARI❋LITE® usan un tipo de lámpara HID que produce radiación UV. NO mire directamente a la lámpara. 2. Es peligroso operar luminarias sin lentes o protectores. Debe cambiar los protectores, lentes o pantallas ultravioletas si se aprecia que han sido dañadas, y que su efectividad pudiera estar deteriorada.
SAFETY NOTICE (JAPANESE) _KHæPÔ HçPÄ ÎÎæ%¿Ð á¿ ~ ÒÁ'êùÕÄQ>X ^Å î ûéQ>X ^é_KHæPÔ ±ãÿ ÔôáÅúÊÛпù ÚsÙæÄ~ ÌÚ öªÔ ÙæêÔôáéHçPÄÅ î TæÐçÒáÞ:ÒáÊÛп ÄQ>X ^âê é_KQo" öªÒá¿ùÔ Hç ~ æÊÍ Ã Â¾Hǽ ùÔ T qPæßåÇ Â¾Hǽ ùÔ õ +4UV |¿æ»Ô 2é:´Å îqP ËÚüé ûxå±æß¿áê éÿ ÅúÊÛп T: +4é¢ ËÚüéEf; 1.
VARI❋LITE - VL2000™ SPOT LUMINAIRE USER’S MANUAL T: 2é UV |¿æÐ Ð å¿ÚüéEf; 1. VARI❋LITE® ÿzUé ÊêUV |¿ ¢Õ HID 2 Jé\fJ öª Òá¿ùÔ\fJ åÞÔ Îãê±ÌáÊÛп _f-ùÚê*o^< ö ÕæÿzU P.Ô ã¾âÔ_f- *o^<¡ "¹Yêíî ÿÓ¿ÞÆÈÍåäæ Øé2 ÇÊå ÁæåÞÚ §Ã ÁæÒùÔ T: qP ËÚüéEf; ÿzUÇP.Òá¿ ãÈêØé ¥Ç²Êå ùÔ²ÊåÞÚzU ÿ&fPo@f; ÒÁÙæê¡¾åUÔ»<ÿ; ª ÜÕ ö ªÒáÊÛп ÿzUÇP.Òá¿ ãÈêØé\fJDzÊå ùÔ\fJ dµ Ô 'êÿzUé . ¾ \fJé÷2Ç Ç ùâÙÞáÊÛ Ð¿\fJécñÚ ½Ì 㤿, 64ÇÛ¿á\fJé .Ç ¾ 'ǽ ùÔ o".
TABLE OF CONTENTS Table of Contents Introduction About This Manual ...................................................................................................... Additional Documentation........................................................................................... Text Conventions ......................................................................................................... Customer Service .....................................................................................
VARI❋LITE - VL2000™ SPOT LUMINAIRE USER’S MANUAL Chapter 3. Operation Color/Gobo Control Color/Gobo Wheel Positions...................................................................................... 26 Standard Colors and Gobos ........................................................................................ 26 Standard Colors - Wheel 1 (Color Wheel)........................................................... 26 Standard Gobos - Wheel 2 (Fixed Gobo Wheel) ..........................................
TABLE OF CONTENTS Cues and Sequences Overview.................................................................................................................... Storing ................................................................................................................. Playback .............................................................................................................. Hardware Requirements .....................................................................................
VARI❋LITE - VL2000™ SPOT LUMINAIRE USER’S MANUAL Notes xvii i 17-Sep-02 02. 9673.
INTRODUCTION : ABOUT THIS MANUAL Introduction About This Manual This manual provides necessary information regarding product safety, installation, operation, and routine maintenance for the VARI❋LITE® VL2000™ Spot Luminaire. Familiarizing yourself with this information will help you to get the most out of your luminaire. WARNING: It is important to read ALL accompanying safety and installation instructions to avoid damage to the product and potential injury to yourself or others.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Text Conventions The following styles and meanings are used throughout this manual: [Button] Front panel button. Example: Press [Menu]. [Up] / [Down] arrows Press either [Up] or [Down] arrow button at Menu Display. MENU Menu Display read-out. Example: Press [Up] / [Down] arrows until CFG (Configuration) appears. Customer Service Our Goal At Vari-Lite, we are committed to providing you the highest quality in customer service.
CHAPTER 1. Description This chapter contains descriptions of luminaire features and components, along with a list of accessories which are available. • Features • Components • Accessories 02.9 673.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Features Overview Standard Features The VL2000 spot luminaire contains the following standard features: 4 • Variable beam focus to soften the edges of gobos or spots and enable gobo morphing. • Full field dimmer to allow smooth timed fades and fast blackouts. • A mechanical iris which provides continuous beam size control for both rapid beam size changes and smooth timed beam angle changes.
DESCRIPTION : COMPONENTS 1 Components VL2000 Spot Luminaire The following illustration shows the major luminaire components and controls.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Menu Display The Menu System Display is used to access the menu system, which is a programmable set of commands used to address, operate, and test the luminaire. The menu system is controlled by four buttons.
DESCRIPTION : ACCESSORIES 1 Accessories Replacement Items/Accessories The following optional and/or replacement items can be ordered directly from Vari-Lite. (Please order by Vari-Lite part number.) 02.9 673.00 01 C Vari-Lite Part No. Accessory 20.9625.0132 Plastic Road Case (Two Hole) 22.9620.0194 Safety Cable Assembly 23.9623.0177 DMX Termination Male Connector Assembly 25.9661.0056 Loopback Connector Assembly 25.9661.0057 DMX Termination Female Connector Assembly 28.9661.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Notes 8 17-Sep-02 02. 9673.
CHAPTER 2. Installation This chapter contains instructions for installation of the luminaire. It includes connecting power and data, along with instructions for powering up the luminaire for the first time and addressing it within your system. • Power and Data Cabling Requirements • Installation Procedures • Powering Up • Addressing 02.9 673.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Power and Data Cabling Requirements Power The luminaire requires standard AC power distribution from 100-240 VAC, 50/60 Hz. Three amps to twelve amps will be required depending on the AC supply voltage and product model. Depending on the application, the luminaire’s AC input cable may require a different connector.
INSTALLATION : POWER AND DATA CABLING REQUIREMENTS 2 Current vs. Voltage The following table provides the luminaire’s current draw at specific voltages. Current is calculated with the lamp on and all motors sequencing. Table 2-1: Current vs. Voltage Voltage @ 60Hz 02.9 673.00 01 C Current 90.0 11.8 100.0 10.6 110.0 9.5 120.0 8.5 130.0 7.9 140.0 7.2 180.0 5.5 190.0 5.2 200.0 4.9 210.0 4.7 220.0 4.5 230.0 4.3 240.0 4.1 250.0 3.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Data Cables The luminaire is equipped with two, 5-pin XLR connectors for DATA IN and DATA THRU (out) applications. DATA IN requires a 5-pin, female XLR connector and DATA THRU requires a 5-pin, male XLR connector. When purchasing or constructing data cables, it is important that not only the correct cable type be used, but also quality cable to ensure a reliable DMX512 system.
2 INSTALLATION : POWER AND DATA CABLING REQUIREMENTS Recommended Cable Types/Manufacturers These are only a few of the suitable cable types. Any quality EIA485, twisted pair, 120 ohm, shielded cable will also work.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Male Termination Connector A male XLR termination connector is required at the last luminaire (or "far end of the line") to prevent signal reflections. Signal reflections may cancel out the signal at certain line lengths, resulting in errors. The terminator is also necessary for software downloads and running tests on multiple luminaires. To construct your own connector, you will need the following components: • 5-pin, male XLR connector.
INSTALLATION : INSTALLATION PROCEDURES 2 Installation Procedures Installing Lamp In the event the lamp was packed separately during shipment, it will be necessary to install in the luminaire before use. WARNING: Ensure that power is removed from luminaire when installing lamp. CAUTION: Wear cotton gloves or other covering while installing lamp. Touching lamp glass with bare fingers will leave oil and may cause the lamp to explode or reduce lamp life.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Hanging the Luminaire The luminaire can be hung horizontally or vertically from any structure designed to work with the type of load created by this moving luminaire. Two truss hook bracket assemblies (provided) are used to attach truss hooks or other mounting hardware as required. Many compatible truss hooks are available from different manufacturers for your particular needs. A minimum of one hook per truss hook bracket is required.
INSTALLATION : INSTALLATION PROCEDURES 2 Step 3. While pulling up on locking mechanism release, fit keyed holes onto raised mounting buttons at bottom of enclosure. Slide forward and release locking mechanism to lock in place. Ensure brackets are locked securely. (Always face brackets in same direction as shown.) WARNING: Ensure that the bracket locking mechanism is fully seated after the bracket is installed on the luminaire.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Installing in Truss: Step 1. Using two people, lift luminaire into mounting position. Step 2. Secure in place with truss hook. Ensure truss hook hardware that locks hook in place (e.g. wing bolt) is properly tightened and that luminaire is fully supported. Step 3. Attach safety cable (as required) as follows : a. Connect one end of cable to luminaire handle. b. Loop at least once around truss/pipe and attach other end of cable to other handle.
INSTALLATION : INSTALLATION PROCEDURES 2 Floor Mounting the Luminaire The luminaire enclosure is sufficient to stabilize the luminaire in a floor installation, provided that the mounting surface is flat and sturdy. Connecting Data and Power A maximum of 32 luminaires may be connected in any one DMX data link. Note: This maximum limit applies to the luminaire "daisy chain" only. Your system or console may require fewer luminaires on a single data link path.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Powering Up Power-Up Procedure Since Lamp On is the default state, the lamp will strike when the luminaire is powered up for the first time. When AC power is applied, the luminaire will immediately begin a calibration sequence that steps it through full pan and tilt movements. The internal color, gobo, and beam mechanisms will also move through a full range of motion.
INSTALLATION : POWERING UP 2 Align Lamp for Flat Field The design of the VL2000 spot luminaire optical system is based on a flat field. A flat field is one where there is no detectable hot spot. After a new lamp is installed, it will be necessary to align the lamp to optimize the beam for the flat field. Knobs located at the luminaire’s backcap will allow adjustment. WARNING: Backcap and adjustment knobs will be HOT during lamp operation. Wear gloves and/or use tools to prevent burns.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Set DMX Mode The VL2000 Series luminaires provide four modes for DMX operation. The mode is set using the luminaire’s Menu Display. • 8-bit Standard - provides one 8-bit DMX channel for control of each luminaire function. • 8-bit Enhanced - provides additional channels for timing control. • 16-bit Standard - provides 16-bit control for pan/tilt.
INSTALLATION : ADDRESSING 2 Addressing Program Starting Address The address setting for DMX console or Virtuoso console controlled systems is entered using the Menu Display. (Refer to “Menu System” chapter on page 51 for detailed instructions.) The luminaire retains the DMX and Virtuoso addresses that are stored even if power is removed. Note: Refer to your console operating instructions for specific information regarding its addressing requirements. Program a DMX or Virtuoso starting address: Step 1.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Notes 24 17-Sep-02 02. 9673.
CHAPTER 3. Operation This chapter contains instructions for operating the luminaire using DMX control and for updating the internal software. • Color/Gobo Control • DMX Modes • DMX Mapping • Luminaire Timing • Updating Software 02.9 673.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Color/Gobo Control Color/Gobo Wheel Positions The standard configurations for color and fixed gobo wheels are: all color filters installed on Wheel 1 (wheel nearest lamp) and all gobos installed on Wheel 2 (wheel nearer to front lens). These wheels each have 12 positions, one being open. Wheel 1 - Colors (Behind plate) Color/Gobo/Iris Bulkhead All rotating gobos are installed on the Rotating Gobo Wheel (nearest to front lens).
OPERATION : COLOR/GOBO CONTROL 3 Standard Gobos - Wheel 2 (Fixed Gobo Wheel) Pebbles Dust Breakup Medium Circles 4 3 Night Sky 5 6 2 7 1 8 12 11 Alpha Rays Leaves Liquid Breakup 9 10 Tribal Breakup Block Wave Breakup Vertical Bars Standard Rotating Gobos open 5 Facet Prism Pinwheel 1 6 2 5 3 4 Circle of Ovals Spiral Stones Hypnospiral 02.9 673.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL DMX Modes 8-Bit and 16-Bit Modes These tables assume a DMX start address of 1. When a different starting address is used, this address becomes channel 1 function and other functions follow in sequence.
OPERATION : DMX MAPPING 3 DMX Mapping Color/Gobo Wheels Table 3-1: DMX Map for Color/Fixed Gobo Wheels % Value DMX (0-255) Wheel Position 0 0 Open Frame 1 % Value 30 2 12 3 13 34 6 35 14 8 9 4 Half Frame 40 16 13 10 17 44 16 45 Full Frame 2 18 18 Half Frame 46 47 19 48 20 49 21 50 50 51 23 52 24 53 25 21 Half Frame 27 02.9 673.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Table 3-1: DMX Map for Color/Fixed Gobo Wheels (Continued) % Value DMX (0-255) Wheel Position % Value 58 23 59 36 37 Half Frame 63 25 64 28 39 100 67 101 40 103 70 104 Full Frame 5 41 42 108 75 109 76 43 44 79 80 Half Frame 82 46 118 85 119 47 87 89 Half Frame 117 84 120 121 88 48 Full Frame 6 90 30 115 116 86 35 112 114 45 83 34 110 113 81 33 Full Frame 7 111 78 32 107 74 77 31 105 106 73 30 102 6
OPERATION : DMX MAPPING 3 Table 3-1: DMX Map for Color/Fixed Gobo Wheels (Continued) % Value DMX (0-255) Wheel Position % Value DMX (0-255) 49 125 Full Frame 8 62 158 50 126 159 127 160 128 63 129 51 52 54 64 56 57 164 132 165 133 65 Half Frame 135 169 137 170 138 67 140 68 142 175 Full Frame 9 69 176 144 177 145 178 70 179 Full Frame 11 180 148 71 181 149 182 150 183 72 Half Frame 153 184 185 73 186 154 187 155 188 156 74 157 02.9 673.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Table 3-1: DMX Map for Color/Fixed Gobo Wheels (Continued) % Value DMX (0-255) 75 191 76 77 Wheel Position % Value DMX (0-255) 88 224 192 225 193 226 194 89 228 196 229 Full Frame 12 90 198 78 79 199 91 233 Spin S CCW 201 234 Stop 235 Stop 236 Stop 237 Spin S CW 92 204 93 205 206 238 Half Frame 207 239 94 208 82 83 209 95 243 211 244 212 96 97 Spin M CW 247 248 Spin F CCW 217 249 98 218 87 245 246 21
OPERATION : DMX MAPPING 3 Rotating Gobo Index/Rotation Table 3-2: DMX Map for Rotating Gobo Index/Rotation % Value DMX (0-255) Wheel Position 0-84 0-215 Index Position 85 216 Fast Spin CW 86-90 217-232 Variable Rates 91 233 Slow Spin CW 92 234-237 Stop 93 238 Slow Spin CCW 94-99 239-254 Variable Rates 100 255 Fast Spin CCW Rotating Gobo Wheel Table 3-3: DMX Map for Rotating Gobo Wheel 02.9 673.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Beam Control Beam Iris Table 3-4: DMX Map for Beam Iris % Value DMX Value Action 0 0 Closed 100 255 Open Edge Table 3-5: DMX Map for Edge % Value DMX Value Action 0 0 Blooms In 100 255 Blooms Out Strobe Table 3-6: DMX Map for Strobe % Value DMX Value Action 0 0-2 Open 1 3-5 Closed 2 6-7 Slow Random 3 8-10 Med Random 4 11-12 Fast Random 5-100 13-255 Speed Range Zoom Table 3-7: DMX Map for Zoom 34 % Value DMX Value A
OPERATION : LUMINAIRE TIMING 3 Luminaire Timing Luminaire Timing Channel Information Timing channel control improves the timed moves of certain groups of parameters. We provide three timing channels, one for Focus (Pan and Tilt), one for color parameters and one for beam parameters. Timing channels support time values of up to six minutes.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Note: Avoid changing timing channel values in a fading cue. This can cause unexpected behavior in the luminaire as the timing channel value is updated over time. Timing channel values and the final destination of the parameters affected by the timing channel should always be sent in a zero count.
OPERATION : LUMINAIRE TIMING 3 Table 3-9: Timing Channels Map (Continued) % Value DMX = Seconds 12 31 6.2 32 6.4 13 33 6.6 34 6.8 35 7.0 36 7.2 37 7.4 38 7.6 39 7.8 40 8 16 41 8.2 42 8.4 17 43 8.6 44 8.8 14 15 18 19 9 46 9.2 47 9.4 48 9.6 49 9.8 50 10 51 10.2 52 10.4 53 10.6 54 11 55 11 56 12 57 12 58 13 23 59 13 60 14 24 61 14 62 14 20 21 22 25 26 27 28 02.9 673.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Table 3-9: Timing Channels Map (Continued) % Value = Seconds 72 18 73 19 74 19 75 20 76 20 77 20 78 21 79 21 80 21 81 22 32 82 22 83 23 33 84 23 85 23 29 30 31 34 35 36 37 38 39 40 41 42 43 44 38 DMX 17-Sep-02 86 24 87 24 88 25 89 25 90 25 91 26 92 26 93 27 94 27 95 27 96 28 97 28 98 29 99 29 100 29 101 30 102 30 103 30 104 31 105 31 106 32 107 32 108 32 109 33 110 3
OPERATION : LUMINAIRE TIMING 3 Table 3-9: Timing Channels Map (Continued) % Value 45 46 47 48 49 50 51 52 53 54 55 = Seconds 113 34 114 35 115 35 116 36 117 36 118 36 119 37 120 37 121 38 122 38 123 38 124 39 125 39 126 39 127 40 128 40 129 41 130 41 131 41 132 42 133 42 134 43 135 43 136 43 137 44 138 44 139 45 140 45 141 45 142 46 56 143 46 144 47 57 145 47 146 47 147 48 148 48 149 49 150 49 151 49 152 50 153 50
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Table 3-9: Timing Channels Map (Continued) % Value 61 62 63 64 = Seconds 154 50 155 51 156 51 157 52 158 52 159 52 160 53 161 53 162 54 163 54 164 54 165 55 65 166 55 167 56 66 168 56 169 56 170 57 171 57 172 58 173 58 174 58 175 59 176 59 177 59 178 60 179 60 67 68 69 70 71 180 65 181 65 182 65 183 70 72 184 70 185 75 73 186 75 187 75 188 80 189 80 190 85 191 85 192 85
OPERATION : LUMINAIRE TIMING 3 Table 3-9: Timing Channels Map (Continued) % Value 77 = Seconds 195 95 196 95 197 95 198 100 78 199 100 200 110 79 201 110 80 81 202 110 203 120 204 120 205 120 206 130 207 130 208 140 209 140 210 140 211 150 212 150 213 160 214 160 215 160 216 170 85 217 170 218 180 86 219 180 220 180 82 83 84 87 88 89 90 91 92 02.9 673.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Table 3-9: Timing Channels Map (Continued) % Value DMX = Seconds 236 250 237 250 238 250 239 260 94 240 260 241 270 95 242 270 243 270 93 96 97 98 99 100 42 17-Sep-02 244 280 245 280 246 290 247 290 248 290 249 300 250 300 251 310 252 310 253 310 254 310 255 Follows Cue Data 02. 9673.
OPERATION : LUMINAIRE TIMING 3 Control Channel Functions The following control actions must be accomplished with zero time transition or with timing disabled. Discrete values must be used and not manual controls such as faders or encoders.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Updating Software Reprogramming Luminaires In some cases, it may be desirable to upgrade the luminaire’s operating software. This process will require a Windows PC, the Luminaire Programming Kit (28.9661.0054), and the VLDownload.exe program. The VLDownload.exe program is available on the VL Download Installer Disk (87.7303.00xx)* or by downloading the Series 1000™ and 2000™ Software Installer.exe from the Vari-Lite website: www.vari-lite.
OPERATION : UPDATING SOFTWARE 3 Install and Reprogramming Procedure This procedure will install the VLDownload.exe program onto the PC and then allow you to reprogram the luminaires. Note: If running Windows NT, you must be working from an account in the Administrators group to install the VLDownload.exe program onto the computer. Install VLDownload.exe program using Programming Disk: Step 1. Insert VL Download Installer Disk into appropriate drive. Step 2. Run Setupex.exe. Step 3.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Step 3. At Select Software to Download section of window, select required luminaire software version to download by clicking its button or select Download All. (Software version is identified by the date and time: MM/ DD/YY HH.MM.) The buttons function as follows: Choice 1 VL2000Spot button downloads the software to all VL2000 spot luminaires. Choice 2 VL2000Wash button downloads the software to all VL2000 wash luminaires.
OPERATION : UPDATING SOFTWARE 3 Step 4. Download will proceed. One of the following will occur: Correct Trouble Luminaire’s green Rx LED will blink rapidly and its menu will display number of blocks received (this number will vary depending on software version being downloaded). This indicates that data is being sent from PC to luminaire.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Transferring Software From Luminaire to Luminaire It is possible to transfer specific software versions between luminaires. As in the case of installing new software versions, multiple luminaires can be programmed at the same time if they are data linked together (refer to “Connecting Data and Power” on page 19), however a maximum of 32 luminaires can be updated at once.
OPERATION : UPDATING SOFTWARE 3 Correct The receiving luminaire’s green Rx LED will blink rapidly and its menu will display number of blocks received (this number will vary depending on software version being downloaded). This indicates that data is being sent from luminaire to luminaire. However, if display does not show blocks as they are received, this indicates that the version being downloaded matches the one already installed or that the luminaire type does not match.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Notes 50 17-Sep-02 02. 9673.
CHAPTER 4. Menu System This chapter contains instructions for operating the luminaire using the Menu Display feature. • Operation • Mapping • Cues and Sequences • Self Tests 02.9 673.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Operation What Is the Menu System? The menu system is a programmable set of commands used to configure, address, operate, and test the luminaire. The menu system is controlled at the Menu Display available at the enclosure input panel. Menu Display The menu system has seven main functions which are referred to as “1st level.” Within these main functions, there can be up to four additional sub-functions (levels 2 thru 5), making five total levels.
MENU SYSTEM : OPERATION 4 To enter the menu system, first press [Menu]. The functions displayed will be 1st level functions. Scroll through the 1st level functions by pressing [Up] / [Down] arrows. Once the desired function appears in the display, press [Enter]. You are now at the 2nd level. Once again, press the [Up] / [Down] arrows to scroll through 2nd level functions. Press [Enter] to access 3rd level functions and so forth.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Default State The menu display’s default state during normal operation is to display the address (Virtuoso or DMX). After 10 seconds of inactivity at the display, it will change to the default state. After longer periods of inactivity, the menu display will switch to its off state. The default state for this feature is 5 minutes, however, different time lengths can also be programmed. To program a different time length for menu off feature: Step 1.
MENU SYSTEM : OPERATION 4 Display Test The Display Test will display every character on the menu display to check for missing characters. The following procedure is used to test the display. Step 1. Press [Menu]. Step 2. Press [Up]/[Down] until Test appears. Press [Enter]. Step 3. Press [Up]/[Down] until DISP appears. Press [Enter]. All segments in the alpha-numeric display should be lit. Shortcuts A few button combinations are provided as shortcuts for frequently used menu functions.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Error Messages If a problem occurs during luminaire calibration, at the end of the calibration sequence the Menu Display will cycle through any applicable error message(s), one a time until the end of the list is reached. To review the error messages again, it will be necessary to access them using the Status function. (Refer to “Troubleshooting” on page 84 for a list of possible causes and remedies associated with the error messages.
MENU SYSTEM : MAPPING 4 Mapping Menu System Overview The following is a graphic representation of the entire menu system.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Menu System Functions Table 4-2: Menu System Functions 1st Level Addr Address CFG System Configuration 2nd Level 3rd Level DMX DMX Address XXX Address value VIRT Virtuoso Address XXXX.
MENU SYSTEM : MAPPING 4 Table 4-2: Menu System Functions (Continued) 1st Level Fixt 2nd Level STAT Status/Error Display Man Manual Commands 4th Level 5thLevel Scrolls error messages * or displays OK Cal Recalibrate OK? Modl Luminaire Model Type XXXX Model Type LId Luminaire ID XXXX. Luminaire ID Number (Page 1) XXXX Luminaire ID Number (Page 2) Ver Version XX.XX. Version (Page 1) XX.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Table 4-2: Menu System Functions (Continued) 1st Level Test* System Test 2nd Level MOVE Pan/Tilt Control 3rd Level Dis Disable Enab Enable ALL Test All Motors 4th Level 5thLevel Press [Menu] to stop tests ALL1 All Synchronized Test ALL2 All Test P/T Pan/Tilt PT 1 Min/Max Fast Pan/TIlt test PT 2 Min/Max SlowPan/Tilt test Pan1 Min/Max Fast Pan Test Pan2 Min/Max Slow Pan Test Pan3 Pan Test Tlt1 Min/Max Fast Tilt Test Tlt2 Min/Max Slow Tilt Test Tlt3 T
MENU SYSTEM : MAPPING 4 Table 4-2: Menu System Functions (Continued) 1st Level 2nd Level Test (cont.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Function Definitions Each menu item is listed in the first column by its display abbreviation. The abbreviations appear in alphabetical order as opposed to their position in the menu display sequence for easy reference. Display 62 Definition Purpose 8 Standard 8-bit Configures luminaire for operation in standard DMX 8-bit mode. 16 Standard 16-bit Configures luminaire for operation in standard DMX 16-bit mode.
MENU SYSTEM : MAPPING Display Definition 4 Purpose Dimm Dimmer Specifies dimmer mechanism for manual control (Man) or tests dimmer/strobe functions (Test). Dis Disable Disables a function. DISP Display Test Tests all 14 segments in the Display. DisP Display Illumination Accesses options for Menu Display on and off times. DMX DMX Accesses functions for setting DMX mode or pan/tilt options (1st level menu) or sets starting address for luminaire in DMX systems (Addr).
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Display 64 Definition Purpose ITim Intensity Time Accepts timing value for intensity fade time. L ON Lamp is On Configures arc luminaire so that lamp will strike upon power up. LAMP Lamp Accesses lamp power up options and information (CFG) or sets beam for lamp alignment adjustment (TEST). LHrs Lamp Hours Displays total number of lamp operating hours.
MENU SYSTEM : MAPPING Display Definition 4 Purpose RHrs Reset Lamp Info Resets lamp hour and lamp strike counters. For use when new lamp is installed. RTST Run-Test Indicates that a system mechanism test is in progress. Sens Sensors Accesses sensor choices for diagnostic testing. SEQ Sequence Playback Sets sequence playback mode to Individual (plays cues from each luminaire) or Master (all luminaires play same cue).
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Cues and Sequences Overview The luminaire has the ability to store and playback cues independent of a console. Cues are stored as numbers from 1 to 99 by using the Cue (Cue Processing) functions available in the menu system. This also allows you to create your own test sequences to be played back on a group of luminaires. Refer to “Menu System Functions” on page 58 for a complete breakdown of Cue and Man (Manual Commands) functions.
MENU SYSTEM : CUES AND SEQUENCES 4 Cue Operations The following section provides instructions for performing cue, sequence, and playback operations. Note: The Mod, Del, PCue, PSEQ commands will all display "---" if no cues have been stored. Note: After 10 seconds of inactivity at the display, it will change to the default state showing the address. To use the menus: The data stored by the luminaire is “last takes precedence.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL To store a cue: Step 1. Press [Menu]. Step 2. Press [Up] / [Down] arrows until Cue appears. Press [Enter]. Step 3. Press [Up] / [Down] arrows until Stor appears. Press [Enter]. The number displayed is the cue number to be stored. Step 4. Press [Enter] to store cue. (Number will increase by one for next cue to be stored.) Step 5. Repeat for remaining cues. To delete a cue: Step 1. Press [Menu]. Step 2. Press [Up] / [Down] arrows until Cue appears.
MENU SYSTEM : CUES AND SEQUENCES 4 To play cues as a sequence: Step 1. Press [Menu]. Step 2. Press [Up] / [Down] arrows until Cue appears. Press [Enter]. Step 3. Press [Up] / [Down] arrows until PSEQ appears. Press [Enter] and the sequence will play. The active cue will be shown in the display. [Enter] to start, [Menu] to stop. To change the follow time in a sequence: The follow time is stored for each cue individually. Step 1. Select cue to be changed from PCue. Step 2.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL To store cues from a console: Step 1. Clear memory by deleting cues or sequence, if required. Step 2. Recall cue at the console. Step 3. From Cue menu, set FLTM, then at Stor store cue. If each luminaire has separate data then store each cue into each luminaire. The sequence mode to use in this case would be ISEQ. 70 17-Sep-02 02. 9673.
MENU SYSTEM : SELF TESTS 4 Self Tests Running Parameter Tests The luminaire is capable of running self tests by using the TEST menu functions. For complete details and values for each test refer to “Diagnostic Tests” on page 73. Note: After 10 seconds of inactivity, the menu display will change to the default state showing the address.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL WARNING: Backcap and adjustment knobs will be HOT during lamp operation. Wear gloves and/or use tools to prevent burns. Lamp The Lamp option has been added to the test menu. This option sets the lamp intensity to 100%, adjusts the iris and edge to produce a hard edge. See “Align Lamp for Flat Field” on page 21 for instructions on lamp adjustment.
MENU SYSTEM : SELF TESTS 4 Diagnostic Tests The following diagnostic tests are available in the test menu. Time is specified for each action in the test, and the total time equals the time it takes to complete each action. If the time is zero the luminaire will perform the test at full speed. )For specific DMX values for each test see “Diagnostic Tests” on page 74.) Test Descriptions ALL1 .................... Tests low voltage power supplies by moving all motors at once. ALL2 ....................
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Table 4-5: Diagnostic Tests Parameters Test Name ALL1 ALL2 74 Pan* Tilt* Dim CWhl F. Gobo Iris R.
MENU SYSTEM : SELF TESTS 4 Table 4-5: Diagnostic Tests (Continued) Parameters Test Name ALL2 (cont.) PT 1 PT 2 Pan1 Pan2 Pan* Tilt* Dim CWhl F. Gobo Iris R.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Table 4-5: Diagnostic Tests (Continued) Parameters Test Name Pan3 Tlt1 Tlt2 Tlt3 Dim1 Dim2 76 Pan* Tilt* Dim CWhl F. Gobo Iris R.
MENU SYSTEM : SELF TESTS 4 Table 4-5: Diagnostic Tests (Continued) Parameters Test Name Dim3 Str Pan* Tilt* Dim CWhl F. Gobo Iris R. Gobo Index Edge Zoom Str time/total time 45167 27000 255 0 0 0 0 0 0 0 0 0/0.5 45167 27000 128 0 0 0 0 0 0 0 0 0/0.5 45167 27000 80 0 0 0 0 0 0 0 0 0/0.5 45167 27000 100 0 0 0 0 0 0 0 0 0/0.5 45167 27000 40 0 0 0 0 0 0 0 0 0/0.5 45167 27000 50 0 0 0 0 0 0 0 0 0/0.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Table 4-5: Diagnostic Tests (Continued) Parameters Test Name Cwl1 Cwl2 Cwl3 78 Pan* Tilt* Dim CWhl F. Gobo Iris R.
MENU SYSTEM : SELF TESTS 4 Table 4-5: Diagnostic Tests (Continued) Parameters Test Name FG 1 FG 2 FG 3 Pan* Tilt* Dim CWhl F. Gobo Iris R.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Table 4-5: Diagnostic Tests (Continued) Parameters Test Name RG 1 RG 2 Irs1 Irs2 EDG1 EDG2 80 Pan* Tilt* Dim CWhl F. Gobo Iris R.
MENU SYSTEM : SELF TESTS 4 Table 4-5: Diagnostic Tests (Continued) Parameters Test Name Zm 1 Zm 3 Pan* Tilt* Dim CWhl F. Gobo Iris R.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Notes 82 17-Sep-02 02. 9673.
APPENDIX A. Troubleshooting and Maintenance This appendix provides instructions for troubleshooting and performing routine maintenance which may be necessary during the life of the luminaire. • Troubleshooting • Routine Maintenance WARNING: All maintenance procedures are to be performed with power removed from the luminaire. Never open removable cover while lamp is in operation. 02.9 673.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Troubleshooting Protecting Your Warranty When performing procedures outlined in the “Troubleshooting Guide” on page 85, observe the following guidelines in order for your luminaire to remain covered by the Vari-Lite Limited Warranty (included in product shipping container). Step 1.
TROUBLESHOOTING AND MAINTENANCE : TROUBLESHOOTING A Troubleshooting Guide If a problem is suspected, try recalibrating the luminaire to prompt an error message. Refer to “Error Messages” on page 56 for more information. The chart below provides possible causes and remedies for each message. CAUTION: Some troubleshooting is included for reference only. Performing remedies marked by gray areas will void product warranty. Refer to “Protecting Your Warranty” on page 84.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Table A-1: Troubleshooting Guide (Continued) Error Display B1M2 Dimm NoSn Description Aux Board 1, Motor 2, Dimmer, Sensor Not Found Possible Cause and Remedy Dimmer power not connected, motor not moving - Connect dimmer power at motor Dimmer sensor not connected - Connect dimmer sensor Dimmer movement restricted or impeded - Remove obstruction Dimmer sensor is faulty - Replace dimmer sensor assembly Aux Board 1 is faulty Replace aux board B1M2 Dimm SAct
TROUBLESHOOTING AND MAINTENANCE : TROUBLESHOOTING A Table A-1: Troubleshooting Guide (Continued) Error Display B2M1 Gobo NoSn Description Aux Board 2, Motor 1, Rotating Gobo Wheel, Sensor Not Found Possible Cause and Remedy Rotating gobo wheel power not connected, motor not moving - Connect rotating gobo wheel power at motor Rotating gobo wheel sensor not connected - Connect rotating gobo wheel sensor Rotating gobo wheel movement restricted or impeded - Remove obstruction Rotating gobo wheel sensor is f
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Table A-1: Troubleshooting Guide (Continued) Error Display Description Possible Cause and Remedy B2M2 Indx SAct Aux Board 2, Motor 2, Rotating Gobo Index, Sensor Always Active Rotating gobo index power not connected, rotating gobo wheel power not connected and both wheel and index aligned with sensor - Connect rotating gobo wheel and index power at motors BRD1 NO COMM Aux Board 1 Communication Failure Aux input connector (J5) not connected to either
TROUBLESHOOTING AND MAINTENANCE : TROUBLESHOOTING A Table A-1: Troubleshooting Guide (Continued) Error Display Description Possible Cause and Remedy PAN SENS ACTV Pan Sensor Always Active Main board pan/tilt connector (J9) disconnected - Connect main board pan/tilt connector (J9) End-of-travel sensor connector (J2) disconnected - Connect end-of-travel sensor connector (J2) SRCH/FOR/ BRD1 BRD2 Searching for Board 1 or 2 Attmepting to communicate with Board 1 or Board 2.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Table A-1: Troubleshooting Guide (Continued) Error Display WRNG SW PROG 90 Description Wrong Software Program 17-Sep-02 Possible Cause and Remedy Software installed does not match luminaire type - Download the correct software for the luminaire 02. 9673.
TROUBLESHOOTING AND MAINTENANCE : ROUTINE MAINTENANCE A Routine Maintenance Lamp Replacement WARNING: Remove power from luminaire before performing maintenance. Parts: 700 Watt Short-Arc Lamp (Vari-Lite part: 71.2528.0700) Tools: Screwdriver, slotted Cotton gloves To replace lamp: Step 1. Remove power from luminaire. WARNING: Lamps will be extremely HOT after operation. Allow lamp to cool before replacing. Step 2. At backcap, using slotted screwdriver (or fingers) turn captive knob until loose. Step 3.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL CAUTION: Wear cotton gloves or other covering while servicing lamp. Touching lamp glass with bare fingers will leave oil and may cause the lamp to explode or reduce lamp life. If required, use alcohol and cotton cloth to thoroughly clean glass portion of lamp. Step 4. Remove lamp by pulling straight out of socket. Step 5. Install new lamp by pressing into socket. Ensure lamp is fully seated in socket and parallel to guide rods.
TROUBLESHOOTING AND MAINTENANCE : ROUTINE MAINTENANCE A Color Filter Replacement WARNING: Remove power from luminaire before performing maintenance. Tools: Screwdriver, Phillips #2 Cotton gloves To remove and replace a color filter: Step 1. Remove power from luminaire. Step 2. At removable cover, using #2 Phillips screwdriver, turn two captive screws one-quarter turn and remove cover. (It will remain attached by tether and lamp wires.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL CAUTION: Do not touch color filters with bare fingers. Wear cotton gloves or other covering while replacing. Clean with glass cleaner and soft cloth if required. Note: In some cases it is easier to slide bulkhead partially out of head assembly to access color filters. To do this, use #2 Phillips screwdriver to turn captive screw onequarter turn and slide bulkhead upward. Disconnect motor connections as necessary. Step 3.
TROUBLESHOOTING AND MAINTENANCE : ROUTINE MAINTENANCE A Fixed Gobo Replacement WARNING: Remove power from luminaire before performing maintenance. Tools: Screwdriver, Phillips #2 Cotton gloves To remove and replace a fixed wheel gobo: Step 1. Remove power from luminaire. Step 2. At removable cover, using #2 Phillips screwdriver, turn two captive screws one-quarter turn and remove cover. (It will remain attached by tether and lamp wires.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL CAUTION: Do not touch gobos with bare fingers. Wear cotton gloves or other covering while replacing. Clean with glass cleaner and soft cloth if required. Note: In some cases it is easier to slide bulkhead partially out of head assembly to access gobos. To do this, use #2 Phillips screwdriver to turn captive screw one-quarter turn and slide bulkhead upward. Disconnect motor connections as necessary. Step 3.
TROUBLESHOOTING AND MAINTENANCE : ROUTINE MAINTENANCE A Rotating Gobo Replacement WARNING: Remove power from luminaire before performing maintenance. Tools: Screwdriver, Phillips #2 Hook and Pick tool (or small slotted screwdriver) Cotton gloves To remove and replace a rotating gobo: Step 1. Remove power from luminaire. Step 2. At removable cover, using #2 Phillips screwdriver, turn two captive screws one-quarter turn and remove cover. (It will remain attached by tether and lamp wires.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Step 4. Locate end of coiled spring which is fitted under carrier tab. Using hook and pick tool or small slotted screwdriver, push end of spring from under tab until it is free. Once free, remove entire coiled spring. Carrier Gobo Spring Tab Flat Locator Markers Flat side Orient flat side to flat side of carrier Spring Free end of spring and then remove CAUTION: Do not touch gobos with bare fingers. Wear cotton gloves or other covering while replacing.
TROUBLESHOOTING AND MAINTENANCE : ROUTINE MAINTENANCE A Cleaning Optical Lenses and Filters WARNING: Remove power from luminaire before performing maintenance. The front lens, color filters, and gobos may require cleaning after extended use. A common glass cleaner can be used along with a soft, lint-free cloth to clean these components. CAUTION: Do not continuously rub filters or it may damage or remove the optical coating. 02.9 673.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Notes 100 17-Sep-02 02. 9673.
APPENDIX B. Technical Specifications Mechanical Intensity Control Full-field dimming designed for both smooth timed fades and strobe effects. Color/Fixed Gobo Wheels Two, 12-position wheels, each providing 11 easily loaded positions (and 1 open) for user-selectable color and gobo choices. Rotating Gobo Wheel Six-position rotating gobo wheel with five rotatable, indexable gobo positions and one open position. Zoom Optics Zoom angle of 2.8 to one. Continuously variable field angle from 19° to 43°.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Optical Source 700 Watt Short-Arc Lamp, 5600°K, 80CRI Reflector Precision glass reflector with dichroic cold mirror coating. Flat field design Operational Power Requirements All VL2000 models are powered through standard AC power distribution and require three amps to twelve amps depending on the AC supply voltage and product model.
B TECHNICAL SPECIFICATIONS : Photometric VL2000 Spot Luminaire - 700W Metal Halide (All data taken with a seasoned light source at 20 hours of life.) CANDELA (cd) BEAM ANGLE (degrees) BEAM DIAMETER TN* FIELD ANGLE (degrees) FIELD DIAMETER TN* NFOV 297,000 15.0 .263 18.5 .326 MFOV 104,000 25.0 .443 30.5 .545 WFOV 50,000 34.5 .621 42.5 .777 LENS * Multiply throw distance by Tn to determine coverage. To calculate Illuminance (I) at a specific distance (D): I = cd 2 D 02.9 673.
VARI❋LITE® - VL2000™ SPOT LUMINAIRE USER’S MANUAL Notes 104 17-Sep-02 02. 9673.
----------------------------------------------------------------------------------------------------------------- Returning Parts for Service Obtaining RMA Number and Returning Parts 1. Contact Service Center. 2. Request Return Material Authorization (RMA) number. 3. If returning VL2000 Series Color/Gobo Bulkheads, remove color and gobo wheel hubs. (Do not remove glass color discs from VL2000 wash luminaire subassemblies). 4. Package all parts being shipped.