User`s manual

VARILITE® - VIRTUOSO™ / VIRTUOSO™ DX CONSOLE USERS MANUAL
64 23-Sep-02 02.9651.0001 C
Storing New Default Min/Max Settings
The min/max buttons associated with each function can be programmed with your
own default settings as required. These settings are referred to as hard/soft, in/out, etc.
depending on the mechanism being controlled. The initial console default settings
(which correspond to the luminaire’s actual min/max values) can be re-stored with
your own min/max settings.
The min/max settings are based on
channel selection. This means that a
different minimum and maximum setting
can be defined for every channel or for
groups of channels as required. For
example, if Channel 1 is patched as a VL5
luminaire you could select its channel and
then store appropriate min/max settings.
You could then deselect Channel 1 and
select Channel 2 (which for example is
patched as a VL6 luminaire) and store
different min/max settings. Depending on
whether Channel 1 or Channel 2 is
selected, the min/max settings would be
different.
Store new min/max settings:
Step 1. Press button for required set of soft encoder functions. It will be mapped to
soft encoders.
Step 2. Select luminaires to be included in min/max setting. (For example, select
some VL6 luminaires.)
Step 3. Using encoders, adjust parameter for new setting.
Step 4. Press [Store] / [Encoder Min/Max Button]. Setting is now stored for those
channels.
Add new channels to a setting:
Step 1. Select luminaires to be added to setting. (For example, select additional VL6
luminaires.)
Step 2. Press [Store] / [Encoder Min/Max Button]. Setting is now stored for new
luminaires as well as previously stored luminaires.
Dyn
Frame
Min/Max Button -
Sends default setting
to selected channels.
(User programmable.)