User`s manual

TUTORIAL : BASIC TUTORIAL
A
02.9651.0001 C 23-Sep-02 331
Add timing and filters to presets and cues:
Refer to Ch. 9 for more detailed instructions.
1. Recall Preset 2 as follows:
a. At Panels menu, choose Select Displays.
b. At Select Displays window, at Group section, click inside Group 1 box.
Channels (luminaires) 1-5 are now selected.
c. At Preset section, click inside Preset 2 box. Luminaires in 3D Graphic
window will move to Preset 2.
Note: When a parameter is not filtered (i.e. highlighted in Filter screen), its data
would be transferred during any subsequent store or recall operations.
2. Filter all parameters except pan and tilt (focus) as follows:
a. At Panels menu, select Timing Display.
b. At Timing Display window, click Filter tab.
c. Click Clear button to deselect all parameters.
d. Click in Pan and Tilt boxes to select for data transfer (only pan/tilt data
will be stored in the preset).
Preset Section
Click inside box 2
to select preset
Filter Tab
Select Pan and
Tilt Filters
Clears all selections
Sends settings to preset/cue store operations