User`s manual

SYSTEM SETUPS : DEFAULT OPTIONS
15
02.9651.0001 C 23-Sep-02 259
Default Explanations
Emergency Action
Default: Do nothing (remain in current state)
This setting determines what event is to occur if communication is lost between the
console and the luminaire/interface devices for longer than 15 seconds. This
information is sent upon console start-up in case of an
emergency. You may determine one of the following:
- Do nothing. Luminaires will do nothing.
- Fade out in n seconds. System will fade out in the specified number of seconds.
- Go to Cue n. Luminaires will assume the specified cue action.
Startup Action
Default: No startup action
This setting determines what event is to occur upon power up of the console. You may
specify one of the following:
- Macro. Console will execute the specified macro.
- Snapshot. Console will execute the specified snapshot.
Date/Time Stamp
Sets the computers internal date and time values for the console.
Units
Default: English
This sets the unit of measure, used with the 2D/3D location configuration.
Palette Store Options
Default: Lowest Active
This setting tells the console whether to draw data from lowest active or lowest
selected channel during a Beam or Color store operation.
The "lowest active" setting draws data from the lowest channel number with intensity
of that type, regardless of selection. The "lowest selected" setting draws data from the
lowest selected channel number of that type, regardless of intensity state.