User`s manual
ADVANCED CUE FEATURES : ADVANCED CUE STORING AND MODIFYING
12
02.9651.0001 C 23-Sep-02 219
Recall stored preset data:
Step 1. At touch screen display, select Filter mode. Using touch screen, select
parameters to be recalled.
Step 2. If timing is desired, press [Man Time]. Recalled parameters will change in
the luminaire’s current time settings.
Step 3. Select channel(s) as required.
Step 4. Press [Recall] [Preset] [x] [Enter] or [Recall] [Preset Select Button]. All
stored data will be recalled from the specified preset (x), as defined by the
selections on the filters.
Undo a Delete Command
In addition to reversing Store and Update commands, the Undo feature can be used to
reverse a Delete command.
Undo (reverse) a Delete command:
• [Undo] [Enter] - reverses the last store/update/delete command.
Modifying Cues in a Submaster
Cues can also be modified and re-stored while active in a submaster. The Store,
Selective Store, and Update commands can be performed by using them in
combination with the submaster’s [Choose] button.
Guidelines:
• When modifying a cue in a submaster, the modified cue data is automatically
loaded into the associated submaster. (Because the loaded cue is subject to altering
by the fader setting, unexpected behavior can occur when that fader setting is less
than full. See “Unexpected Behavior” below.)
• Only channels receiving instructions from the cue being modified will be changed.
latest str/upd/del
Undo *
FE
CG
I
B