Mechanical construction
Design, dimensions
L00-NRF590-06-00-06-yy-001
Construction The NRF590 housing has three separate compartments, one containing all electronics and two for electrical
connections. The enclosure is die-cast aluminum with an polyester coating and IP65 (NEMA 4) rating. The
upper terminal compartment and electronics compartment are designated for non-i.s. connections and
electronics and are rated EEx d.The lower terminal compartment is designated for i.s. wiring connections and
wiring only.
Weight approx. 8 kg
Cable entries The non-i.s. terminal compartment has 3 cable entries. The threading in this terminal compartment enclosure
is M20x1.5.
All intrinsically designated wiring has to be terminated in the i.s. terminal compartment. For the i.s. wiring,
two M25x1.5 cable entries are available.
The internal diameter of the cable entry is 16 mm.
For accommodating various types of cable glands or cable conduit (rigid or flexible), the following sizes of cable
gland adapters are optionally available:
M20x1.5
•G½
•½" NPT
¾" NPT (max. 2 cable entries)
All adapters are rated EEx d and can be used for either cable connection. When installing, properly seal all ports
to prevent moisture or other contamination from entering the wiring compartments.