Specifications
83
Reference Manual
00809-0100-2460, Rev AA
Section 6: Service and Troubleshooting
November 2014
Service and Troubleshooting
4. Enable ports to be logged by checking the corresponding check box.
5. Specify maximum file size and maximum number of log files.
6. Specify log destination USB or SD card. The log files will be stored in a folder named
“comlogs”. File names will be given by the following syntax:
“ComLog_Port<1-8>_<01-10>.txt”.
Example: “ComLog_Port2_03.txt” refers to the third log file for communication port
number 2.
7. Setup advanced filtering options for the ports to be logged. For each port you may
choose:
a. any address or a specific address
b. function code
c. status, i.e. various error types
8. Click the Apply button to start logging.
Logging will continue until it is stopped manually as described in “To stop logging” on
page 84.
When the maximum number of files is reached, the first file will be overwritten. If no log filtering
is applied to a port, communication events for approximately 18-20 hours, equal to 100 MB of
data (maximum 10 files and 10 MB of data per file), will be available before being overwritten by
newer communication events.