Specifications

51
Reference Manual
00809-0100-2460, Rev AA
Section 4: Configuration
November 2014
Configuration
c. Select the Field Port that the device is connected to.
In the standard configuration there are six field bus ports available for the 2460 System
Hub. The TRL2 bus is the standard field bus interface for devices connected to a
Rosemount 2460 System Hub. See “Connecting the 2460 System Hub” on page 29 for
more information.
d. Enter the 2410 Device Address for each 2410 Tank Hub that is connected to the 2460.
Note that for 2410 Tank Position 1 the same address will be used for the Temperature
Device and the 2410 Tank Hub itself. This is handled automatically by TankMaster.
e. Enter the appropriate 2410 Tank Position. Field devices on a certain tank are
associated with the same Tank Position in the Tank Database for the 2410 Tank Hub. For
a 2410 connected to one tank only, all field devices are configured in Tank Position 1.
See “Single tank connected to a single 2410 Tank Hub” on page 55 for an example of
how to configure a 2460 System Hub connected to 2410 Tank Hubs with one tank
each.
Use Tank Position 2-10 for the multiple tanks version of the 2410 Tank Hub. It has a
database with 10 tank positions that allows the 2410 to serve up to ten tanks. Each row
in the Tank Database of the 2460 System Hub corresponds to a tank position in the
2410 database.
See “Multiple tanks connected to a single 2410 Tank Hub” on page 58 for an example
of how to configure a 2460 connected to a 2410 with three tanks.
Important! The Tank Database of the 2460 System Hub must be properly configured
to match the Tank Databases of all 2410 Tank Hubs connected to the 2460.
f. Enter Level Device Address for devices such as the Rosemount 5900S Radar Level
Gauge and other level gauges supported by the 2460 System Hub and the 2410 Tank
Hub.