Function “process cond.” (004)
This function is used to select the process conditions.
Selection:
standard
calm surface
turb. surface
agitator
fast change
heavy conditions
test: no filter
Note The phase evaluation of the 7500 series RTG (see page 55) is only activated
if you select the measuring conditions “standard”, “calm surface” or "heavy
conditions”. If, however, "heavy conditions” is selected, no index values are stored.
We strongly recommend that, in the case of rough product surfaces or rapid filling,
you activate the appropriate application parameters.
E
+
standard calm surface
For all applications that do not fit into any of
the following groups.
Storage tanks with immersion tube or bottom
filling.
The filter and output damping are set to
average values.
The averaging filters and output damping are
set to high values.
steady meas. value
precise measurement
slower reaction time