6.3.2 Unlocking configuration mode
If an attempt is made to change parameters when the device is locked, the user is
automatically requested to unlock the device:
Function “unlock parameter” (0A4):
By entering the unlock parameter (on the display or via communication)
100 = for HART devices
the 7532 RTG is released for operation.
Hardware unlock:
After pressing the keys at the same time, the user is asked to enter
the unlock parameter.
100 = for HART devices.
Table 6-7: Hardware Unlock
Caution! Changing certain parameters such as all sensor characteristics, for
example, influences numerous functions of the entire measuring system,
particularly measuring accuracy. There is no need to change these parameters
under normal circumstances and consequently, they are protected by a special code
known only to the Varec service organization. Please contact Varec, Inc. if you have
any questions.
6.3.3 Factory settings (Reset)
Caution! A reset sets the device back to the factory settings. This can lead to an
impairment of the measurement. Generally, you should perform a basic setup again
following a reset.
A reset is only necessary if the device...
• ... no longer functions
• ... must be moved from one measuring point to another
• ... is being uninstalled /put into storage/installed