Instruction manual

7532 Radar Tank Gauge
Varec, Inc. 19
4.4.3 Turn housing
After mounting, the housing can be turned 350° in
order to simplify access to the display and the
terminal compartment. Proceed as follows to
turn the housing to the required position:
1. Undo the fixing screws (1)
2. Turn the housing (2) in the required direction
3. Tighten up the fixing screws (1)
Figure 4-8: Turn Housing
1
2
T12 housing
A
llen key
4 mm
tighten strongly
by hand