Instruction manual

Mounting
12 Installation and Operations Manual
4.3 Installation Conditions
4.3.1 Dimensions
Figure 4-2: 7532 RTG Dimensions
Note The inactive length of 60 mm prevents condensation effects to the antenna
performance. Special versions with longer construction are available.
65
(2.56)
Ø 129 (5.08")
Ø 150 (5.91)
Ø d
68
(2.68)
94
(3.7)
30
(1.18)
L
238 (9.37)
60
(2.36)
8 (0.31)
85
(3.35)
DIN, ANSI,
JIS, JPI
9
(0.35)
Ø 62,5 (2.46)
Ø 78 (3.07)
Ø 99,5 (3.92)
mm (inch)
DN 150 / 6" DN 200 / 8" DN 250 / 10" DN 300 / 12"
L
d
111
(4.37)
355
(14)
192
(7.56")
508
(20)
242
(9.53")
535
(21.1)
292 ‚
(11.5")
DN 150
22 (0.86)
[28 (1.10)]
285 (11.2)
[300 (11.8)]
b
D
DN 200
24 (0.95)
[30 (1.18)]
340 (13.39)
[360 (14.17)]
DN 250
26 (1.02)
405 (15.95)
DN 300
28 (1.1)
460 (18.1)
6"
25.4 (1)
[36.6 (1.44)]
279.4 (11)
[317.5(12.5)]
b
D
8"
28.4 (1.12)
[41.1 (1.62)]
342.9(13.5)
[381(15)]
10"
30.2 (1.19)
406.4(16)
12"
31.8 (1.25)
482.6(19)
b
D
8"
28.6
(1.12)
345
(13.58)
10"
30.2
(1.19)
405
(15.95)
DN 150
22 (0.86)
[28 (1.10)]
280 (11.02)
[305 (12)]
b
D
DN 200
22 (0.86)
[30 (1.18)]
330 (12.99)
[350 (13.78)]
DN 250
24 (0.95)
400 (15.75)
6"
25.4
(1)
280
(11.02)
12"
31.8
(1.25)
485
(19.1)
6"
280
(11)
D
8"
340
(11.4)
10"
405
(15.9)
12"
482
(19)
111 (4.37)
for PN 1
E+H UNI Flange (see page 33)
Flange
for 10 K [for 20 K]
Flange to JIS B2220
Flange
for 150 lbs
Flange to JPI 7S - 15
for 150 lbs [for 300 lbs]
Flange to ANSI B16.5
for PN 16 [for PN 25]
Flange
Flange to EN 1092-1 (agreeable to DIN2527)
no Horn
Antenna
version (Ø d)
DN200…300 / 8…12”
ver sion with
antenna widening
E+H UNI ange
(max. 1 bar)
ange hub
mounting:
4 bolts M6 / 90°
e.g. DIN 912
O-Ring 85.3 x 3.53,
included
(same mater ial as
sensor seal)
DN150 / 6”
ver sion without widening
detail A:
ange adapter
(see under)
detail A
ange hub f or the connection
to anges pro vided by the customer
inactive length