User's Manual

VT-MOD-CELL-B48 Hardware User Manual
10
4.3 Temperature
Table 3-2 Operating and storage temperature
Parameter
Description
Minimum
Maximum
Unit
To
Operating temperature
-20
65
Ta
Operating temperature (Reduced
RF performance)
-30
70
Ts
Module storage temperature
-40
85
Relative storage humidity 5% 95%
4.4 Digital Signal DC Characteristics
It is recommended that the application conditions for VT-MOD-CELL-B48 are as
follows. Wherein, VDD_IO = 1.8V.
Table 3-3 VT-MOD-CELL-B48 Recommended application conditions
Parameter
Description Minimum Value Maximum Value
Unit
VIH High-level input voltage 1.26 2.1 V
VIL Low-level input voltage -0.3 0.54 V
VOH High-level output voltage
VDD_IO V
VOL Low-level output voltage
V
4.5 Power Supply and Consumption
4.5.1 Input Power Supply
For VT-MOD-CELL-B48, the input voltage range is 3.15~4.2 V, which is supplied
from the Module connector.
Table 3-4 Power specifications
Parameter Description
Minimum value Maximum value Unit
VCC_3V3
3.15 3.3 4.2 V