Installation manual
www.fmiproducts.com
113195-01N20
OPERATION
Continued
Ignitor
Electrode
Pilot
Burner
Figure 29 - Pilot
Natural Gas
Ignitor
Electrode
Pilot Burner
Propane/LP Gas
TO TURN OFF GAS
TO APPLIANCE
1. Turn control knob clockwise to the
OFF position.
2a. Set selector switch in the OFF position.
2b. If Using Optional Hand-Held Remote:
Set remote selector switch in the OFF
position to keep from draining battery.
3. Close equipment shutoff valve (see Figure
17, page 15).
MANUAL LIGHTING
PROCEDURE
1. Follow steps 1 through 6 under Lighting
Instructions, page 18.
2. Press control knob and light pilot with
match.
3. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob. Now follow steps 9
through 11 under Lighting Instructions,
column 1.
OPTIONAL HAND-HELD
REMOTE OPERATION
Note: All remote control accessories must
be purchased separately (see Accessories,
page 33). Follow instructions included with
the remote control.
NOTICE: You must light the pilot
before using the hand-held re-
mote control unit. See Lighting
Instructions on page 18.
After lighting, let pilot ame burn for about
one minute. Turn control knob to ON posi-
tion. Adjust ame adjustment knob anywhere
between HI and LO. Slide selector switch to
REMOTE position (see Figure 30).
Note: The burner may light if hand-held re-
mote was on when selector switch was last
turned off. You can now turn burner on and off
with hand-held remote control unit.
IMPORTANT: Do not leave selector switch in
the REMOTE or ON position when pilot is not
lit. This will drain battery.
Figure 30 - Setting the Remote Selector
Switch, Control Knob and Flame
Adjustment Knob for Remote Operation
Flame
Adjustment Knob
Remote Selector Switch in
Remote Position (Optional
Hand-Held Remote Control)
Control Knob
in On Position
OPTIONAL BLOWER
OPERATION
Locate blower switch by opening lower louver
on replace insert. Blower switch is located at
lower left inside louver door.
This thermostat-controlled blower has three
settings: ON, OFF and AUTO. In the ON
position, blower will operate constantly. In
the OFF position, blower will not operate.
In the AUTO position, blower will start when
thermostat senses a sufcient increase in
rebox temperature.
Note: Your gas logs and thermostat blower
will not turn on and off at the same time. The
replace insert may run for several minutes
before blower turns on. After heater modulates
to pilot position, blower will continue to run.
Blower will shut off after rebox temperature
decreases.
Note: It is safe to operate replace insert with
blower turned off. However, blower helps dis-
tribute heated air from replace insert.