Installation manual

www.fmiproducts.com
113195-01N 19
O
F
F
P
I
L
O
T
L
O
I
H
AUTO
OFF
ON
O
N
Figure 28 - Control Knob and Ignitor
Button Location (Shown as Supplied, No
Control Options)
Control
Knob
Ignitor Button
Flame
Adjustment
Knob
Selector Switch
NOTICE: During initial operation
of new replace insert, burning
logs will give off a paper-burning
smell. Open damper or window
to vent smell. This will only last
a few hours.
1. STOP! Read the safety information col-
umn 1.
2. Make sure equipment shutoff valve is fully
open.
3. Set switch to OFF position.
WARNING: Burners will
come on automatically within
one minute when the remote
selector switch is in the ON posi-
tion after the pilot is lit.
4. Press in and turn control knob clockwise
to the OFF position.
5. Wait ve (5) minutes to clear out any gas.
Then smell for gas, including near the
oor. If you smell gas, STOP! Follow “B”
in the safety information in column 1. If
you don’t smell gas, go to the next step.
6. Press in and turn control knob counter-
clockwise to the PILOT position.
Press in control knob for ve (5) seconds
(see Figure 28).
Note: You may be running this heater
for the rst time after hooking up to gas
supply. If so, the control knob may need
to be pressed in for 30 seconds or more.
This will allow air to bleed from the gas
system.
OPERATION
Continued
7. With control knob pressed in, press and
release ignitor button. This will light pilot.
The pilot is attached to the front burner. If
needed, keep pressing ignitor button until
pilot lights.
Note: If pilot does not stay lit, contact a
qualied service person or gas supplier
for repairs. Until repairs are made, light
pilot with match. To light pilot with match,
see Manual Lighting Procedure.
8. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob.
If control knob does not pop out when
released, contact a qualified service
person or gas supplier for repairs.
Note: If pilot goes out, repeat steps 4
through 8.
9. Slightly push in and turn control knob coun-
terclockwise to the ON position.
10. Wait one minute and switch selector switch
to the ON position to light burners.
11. Set ame adjustment knob to any level
between HI and LO.
12. To leave pilot lit and shut off burners only:
turn control knob clockwise to the
PILOT position, or use remote control
manual OFF button, or set selector switch
in the OFF position.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
WARNING: Make sure the
selector switch is in the OFF
position when you are away from
home for long periods of time.
Heater will come on automati-
cally with selector switch in the
ON position.