Installation manual
www.fmiproducts.com
113195-01N18
INSTALLATION
Continued
OPTIONAL WIRELESS HAND-HELD
REMOTE CONTROL ACCESSORIES
(MRC and TRC)
Installing Remote Receiver Unit
1. Disconnect switch wires from control valve.
2. Remove screws attaching switch plate.
3. Remove switch plate (see Figure 26).
Discard after removing.
4. Install remote receiver unit onto gas log
heater base or set on replce oor.
5. Connect wires as shown in Figure 27.
Figure 26 - Switch Plate and Wiring
Harness
Screw
Switch
Plate
Wires
Remote Switch
Bracket
Ignitor
Figure 27 - Connecting Wires
Red Wire From
Receiver
Valve
White
Wire From
Receiver
OPERATION
FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not fol-
low these instructions exactly,
a re or explosion may result
causing property damage, per-
sonal injury or loss of life.
A. This appliance has a pilot which must
be lighted by hand. When lighting
the pilot, follow these instructions
exactly.
B. BEFORE LIGHTING smell all around
the appliance area for gas. Be sure to
smell next to the oor because some
gas is heavier than air and will settle
on the oor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do
not use any phone in your building.
• Immediately call your gas supplier
from a neighbor’s phone. Follow the
gas supplier’s instructions.
• If you cannot reach your gas supplier,
call the re department.
C. Use only your hand to push in or turn
the gas control knob. Never use tools.
If the knob will not push in or turn by
hand, don’t try to repair it, call a quali-
ed service technician or gas supplier.
Force or attempted repair may result in
a re or explosion.
D. Do not use this appliance if any part
has been under water. Immediately
call a qualied service technician to
inspect the appliance and to replace
any part of the control system and
any gas control which has been under
water.
LIGHTING
INSTRUCTIONS
WARNING: You must oper-
ate this heater with the replace
insert screen in place. Make
sure replace insert screen is
installed before running re-
place insert.