4. Check all joints of gas supply piping sys-
tem. Apply a noncorrosive leak detection
uid to all joints. Bubbles forming show a
leak.
5. Correct all leaks at once.
6. Reconnect replace insert and equipment
shutoff valve to gas supply. Check recon-
nected ttings for leaks.
Test Pressures Equal To or Less Than
1/2 PSIG (3.5 kPa)
1. Close equipment shutoff valve (see Fig-
ure 17).
2. Pressurize supply piping system by either
opening propane/LP supply tank for pro-
pane/LP gas or opening main gas valve
located on or near gas meter or using
compressed air.
3. Check all joints from gas meter to equip-
ment shutoff valve for natural gas (see
Figure 18) or propane/LP supply to
equipment shutoff valve for propane/LP
(see Figure 19). Apply a noncorrosive
leak detection uid to all joints. Bubbles
forming show a leak.
4. Correct all leaks at once.
Figure 17 - Equipment Shutoff Valve
Equipment
Shutoff
Valve
Figure 18 - Checking Gas Joints (Natural
Gas)
Manual Gas Valve
Figure 19 - Checking Gas Joints
(Propane/LP Gas)
Equipment Shutoff Valve
Manual Gas Valve
Open
Closed
Equipment
Shutoff
Valve
Gas
Meter
Propane/LP
Supply
Tank
PRESSURE TESTING FIREPLACE
INSERT GAS CONNECTIONS
1. Open equipment shutoff valve (see Fig-
ure 17).
2. Open main gas valve located on or near
gas meter for natural gas or open pro-
pane/LP supply tank valve.
3. Make sure control knob of replace insert
is in the OFF position.
4. Check all joints from gas meter to equip-
ment shutoff valve for natural gas (see
Figure 18) or propane/LP supply to
equipment shutoff valve for propane/LP
(see Figure 19). Apply a noncorrosive
leak detection uid to all joints. Bubbles
forming show a leak.
5. Correct all leaks at once.
6. Light fireplace insert (see Operation,
page 18). Check all other internal joints
for leaks.
7. Turn off replace insert (see To Turn Off
Gas to Appliance, page 20).
FIREPLACE INSERT INSTALLATION
INTO MASONRY FIREPLACE
Installation of this replace insert involves
installing fireplace insert into an existing
masonry replace. If using a mantel above
the replace, you must follow the clearances
shown in Figure 12, page 12. Follow instruc-
tions below to install replace insert in this
manner.
1. Use dimensions shown in Figure 20, page
16 for masonry replace opening.
2. Install and properly ground GA3555, three-
prong 120 volt electrical outlet, in replace
insert. Follow instructions included in kit
(see Accessories, page 33).