Installation manual

www.fmiproducts.com
123502-01E 29
SPECIFICATIONS
THERMOSTAT MODELS

Rating (Variable): 17,000/26,000 Btu/Hr
Type Gas: Propane/LP
Ignition: Piezo
Manifold Pressure: 8" W.C.
Inlet Gas Pressure (in. of water):
Max - 14" W.C., Min* - 11" W.C.

Rating (Variable): 17,000/26,000 Btu/Hr
Type Gas: Natural
Ignition: Piezo
Manifold Pressure: 3.5" W.C.
Inlet Gas Pressure (in. of water):
Max - 10.5" W.C., Min* - 5" W.C.
* For purpose of input adjustment
REMOTE-READY MODELS

Rating (Variable): 17,000/26,000 Btu/Hr
Type Gas: Propane/LP
Ignition: Piezo
Manifold Pressure: 8" W.C.
Inlet Gas Pressure (in. of water):
Max - 14" W.C., Min* - 11" W.C.

Rating (Variable): 17,000/26,000 Btu/Hr
Type Gas: Natural
Ignition: Piezo
Manifold Pressure: 3.5" W.C.
Inlet Gas Pressure (in. of water):
Max - 10.5" W.C., Min* - 5" W.C.
* For purpose of input adjustment
When calling, have ready:
your name
your address
model and serial numbers of your heater
how heater was malfunctioning
purchase date
Usually, we will ask you to return the part to
the factory.
REPLACEMENT PARTS
Note: Use only original replacement parts.
This will protect your warranty coverage for
parts replaced under warranty.

Contact authorized dealers of this product.
If they can’t supply original replacement
part(s), call FMI PRODUCTS, LLC at
1-866-328-4537.
SERVICE HINTS

pilot will not stay lit
burners will have delayed ignition
replace will not produce specied heat
for propane/LP units, propane/LP gas sup-
ply may be low
You may feel your gas pressure is too low. If
so, contact your local natural or propane/LP
gas supplier.
TECHNICAL SERVICE
You may have further questions about
installation, operation, or troubleshooting.
If so, contact FMI PRODUCTS, LLC at
1-866-328-4537. When calling please have
your model and serial numbers of your
heater ready.
You can also visit FMI PRODUCTS, LLC’s
web site at .