Installation manual
www.fmiproducts.com
123502-01E20
MANUAL LIGHTING
1. Follow steps 1 through 5 under Lighting
Instructions, beginning on page 18.
2. With control knob pressed in, strike match.
Hold match to pilot until pilot lights.
3. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob. Now follow step 8
under Lighting Instructions, column 2.
BLOWER
This blower has three settings: ON, OFF and
AUTO. In the ON position, the blower will oper-
ate constantly. In the OFF position, the blower
will not operate. In the AUTO position, the
blower will start when the thermostat senses a
sufcient increase in rebox temperature.
Figure 28 - AUTO/OFF/ON Blower Switch
AUTO/OFF/ON Switch
REMOTE-READY MODELS
OPERATION Continued
THERMOSTAT-CONTROLLED MODELS
the appliance and to replace any part of
LIGHTING
INSTRUCTIONS
WARNING: You must operate
screen is installed before run-
WARNING: Burner will come
on automatically within one min-
ute when control valve is in the
Note: Your replace and thermostat blower
will not turn on and off at the same time.
The replace may run for several minutes
before the blower turns on. After the heater
modulates to the pilot position, the blower will
continue to run. The blower will shut off after
the rebox temperature decreases.
Note: It is safe to operate replace with blower
turned off. However, the blower helps distrib-
ute heated air from the replace.
FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not fol-
low these instructions exactly,
-
-
BEFORE LIGHTING smell all around the ap-
WHAT TO DO IF YOU SMELL GAS
Use only your hand to push in or turn the
-