Installation manual

www.fmiproducts.com
123502-01E 17
INSTALLATION
Continued
WARNING: Do not con-
nect the thermostat to a power


6. Connect one bare wire end to each termi-
nal (“W” and “R”) of the thermostat base
(see Figure 23).
Figure 22 - Back View of Thermostat Base
Feed wires through
rectangular slots
W
R
Figure 23 - Thermostat Base Terminals
“W” and “R”
Terminal “W”
Terminal “R”
Figure 21 - Connecting Wire Terminals
To Wall
Thermostat
or Switch
To Wall
Thermostat
or Switch
Control Valve


WARNING: Read and fol-
  
Installation should be done by


WARNING: Do not connect
this switch to any electrical


1. Remove jumper wire from control valve
(see Figure 19, page 16).
2. Connect one terminal of 25 ft. wire to the
“TH” terminal on the control valve. Con-
nect other terminal to the “THTP” terminal
on control valve. See Figure 21.
3. Route the 25 ft. wire to a convenient loca-
tion to mount your wall switch (no outside
walls).
WARNING: Do not connect
     
-

IMPORTANT: The wire may be shortened but
must not be lengthened.
4. Connect one bare wire end to each of the
terminals of the provided wall switch.
5. Install the wall switch and cover in the
wall.
7. Install base onto wall with provided
screws.
8. Move temperature adjustment back and
forth to insure the bimetal is free from
restrictions.
9. Replace cover onto base. (Upon installa-
tion, thermostat must be allowed to sta-
bilize at room temperature for a minimum
of 30 minutes for proper operation).
10. Set temperature adjustment to desired
setting. This thermostat has been elec-
tronically calibrated at the factory. No
adjustment or leveling is necessary.