Installation manual
www.fmiproducts.com
123502-01E14
INSTALLATION
Continued
We recommend that you install a sediment
trap in supply line as shown in Figure 13, page
13. Locate sediment trap where it is within
reach for cleaning. Install in piping system
between fuel supply and heater. Locate sedi-
ment trap where trapped matter is not likely
to freeze. A sediment trap traps moisture and
contaminants. This keeps them from going
into replace controls. If sediment trap is not
installed or is installed wrong, replace may
not run properly.
CONTROL
Installation Items Needed
• Phillips screwdriver
• sealant (resistant to propane/LP gas, not
provided)
1. Open lower louver (see Figure 14).
is provided to allow accessibility
-
nection to the equipment shutoff
2. Route exible gas line, included, from
fireplace control to equipment shutoff
valve through side access holes in outer
casing.
3. Apply pipe joint sealant lightly to male
threads of gas connector attached to
exible gas line/equipment shutoff valve
(see Figure 15).
-
Figure 14 - Flexible Gas Line Location
(Remote-Ready Unit Shown)
Lower
Louver
Flexible Gas
Line
Figure 15 - Attaching Flexible Gas Line
to Equipment Shutoff Valve
Flexible Gas Line
from Fireplace
Gas Regulator
Provided With
Fireplace
To Gas Regulator (Thermostat-
Controlled Models) or Control
Valve (Remote-Ready Models)
Equipment
Shutoff
Valve
To External Regulator
NATURAL GAS
To Gas Supply
and connections, internal and
external to unit, for leaks after
WARNING: Never use an
Apply a noncorrosive leak detec-
4. Check all gas connections for leaks. See
Checking Gas Connections, below. Feed
exible gas line into replace. Make sure
the entire exible gas line is in replace.










