Specifications
V A N T A G E
®
Installation
1061 S OUTH 800 E AST • O REM, U TAH 84097 • T ELEPHONE 801.229.2800 • F ACSIMILE 801.224.0355 • www.vantagecontrols.com
Overview
The Vantage AccentPoint Relay II connects to the Vantage
Control System through RadioLink®. It enables an appliance to
be controlled by a keypad, timed event, IR button, etc. It has two
loads and one button for each load with default programming to
allow for local control of the appliance whether the station is
communicating with the Vantage system or not.
Specifications
Description Specification
Dimensions, HWD
4.125” x 3.125” x 1.25”
107.95mm x 79.37mm x 31.75mm
Weight 5.8 oz - 164g
Mounting Plugs into standard 120VAC Outlet
Voltage 120V, 60Hz
Max. Load
• 16A (shared between both outlets) for General
Purpose AC, Magnetic Low-Voltage, and resistive
loads, i.e., if one outlet is using the full 16A limit, the
other outlet must not be used.
• 1 Horsepower (16A) for motor loads
• 8A per outlet (16A total) for incandescent loads
Lightning / Surge
Protection
High Voltage meets IEEE C62.41 (6000V & 3000A)
Low Voltage meets ITU-T K.20
Station Equivalent 1 RadioLink Station
Ambient Operating
Temperature
32 - 95°F -or- 0 - 35°C
Ambient Operating
Humidity
5 - 95% non-condensing
LED Indicator Status
Load Types
General purpose AC, magnetic Low-voltage, and resistive
loads, motor loads, incandescent loads
UL and CUL Listed Yes
FCC Yes
System Requirements
This station is compatible with InFusion Design Center Systems.
For new projects it is recommended that firmware and software
be kept to the most current release.
Installation
Installation of Vantage products should be performed or
supervised by a Certified Vantage Installer.
1. Make sure the appliance to be controlled is turned OFF.
2. Plug the appliance into the load 1 or load 2 outlet on the
bottom of the AccentPoint.
3. Plug the AccentPoint into the bottom receptacle of a power
outlet. Notice the plug of the AccentPoint Relay II Station
may be rotated 180°. If the GND prong on the outlet is UP,
rotate the plug as illustrated so the Load Outlets are facing
down (recommended).
4. Turn the appliance switch to ON
5. It is now ready to be controlled by the Vantage system.
Steps to Rotate the Outlet
The plug should only be rotated once. Only rotate when
necessary as described in step 3 above.
1. Use a precision grade Phillips #1 screw driver to remove
the screw from the plug assembly of the station.
2. Pull the plug assembly out by hand and rotate it 180°
3. Reinsert the plug by hand. Line it up and press it in until
the face of the plug assembly is flush with the case.
4. Fasten the plug assembly with the screw removed in
step 1.
5. Do not over tighten.
Station Set Up in Design Center Software
1. Select the room
2. Click on Vantage Objects in the Object Explorer and
expand Stations, RadioLink.
3. From the list of stations double click on the AccentPoint
Relay II station to place it in the room.
4. In the Object Editor, name the station and make sure it is
on the correct RadioLink bus port.
Configuration
RadioLink stations need to be configured to associate which
physical station goes with the station in software. When the
station is initially powered-up, the Status LED will blink three
times followed by a pause - this means the station is powered
correctly but not yet on the network. Before uploading the file to
the Vantage system, do the following:
1. In Design Center with the AccentPoint Relay II highlighted,
in the Object Editor click in the Serial Number section
2. Manually type in the serial number of the AccentPoint
Dimmer II station. enter the serial number for each
RadioLink
3. Repeat for each AccentPoint Relay II station
4. TIP: The serial number of each station is located on a
permanent sticker on the station. Record this number for
easy reference when programming in Design Center.
5. When the InFusion System is programmed, the Main
Controller will add all RadioLink stations that it has serial
numbers for. This may take several minutes depending on
the number of RadioLink stations on the network.
6. The Status LED will blink steadily when logged on to the
network.
Device Operation
The AccentPoint Relay II is designed to be controlled from a
separate keypad, timed event or other control on the Vantage
System. It also has a button for local control of each load. The
buttons operate with default programming whether or not the
device is communicating with the Vantage System. Pressing the
buttons toggle the loads on and off.
When power is restored from a power outage the device will
return the load to the last load state. This will occur whether or
not the station is connected to a system.
Reset
The device stores the configuration data locally so that it will
continue to operate correctly if communication with the system is
lost. To reset this information to the factory default, unplug the
device, press and hold both buttons in and plug it in while
holding the buttons down. After a reset the load will be off, and
other settings will be at factory default.
Note: Make sure it is back on-line with the Master Controller
before testing button or load operation.
RadioLink®
AccentPoint Relay II
—
APREL