Owner`s manual

TSR-2 Remote Control
TruSine 4.5 kW Inverter Page 14 Owners Manual
MONITOR Menu:
20 AUTOSCAN System status display Go to Step 30
21 MANUAL SCAN System status display Go to Step 40
AUTOSCAN Menu:
30 Press ESC to quit. Go to 31
31 Inverter/Charger/System Displays inverter status message Go to 32
SYSTEM STATUS
32 APM Limit Displays APM setpoint Go to 33
XX Amps AC
33 Aux AC Input Displays if Aux AC Input is within voltage Go to 34
ERROR and frequency tolerance
34 System AC Volts Displays Aux AC input volts or Go to 35
XXX VAC inverter AC output volts
35 System AC Amps Displays Aux AC input amps or Go to 36
XXX Amps AC inverter AC output amps
36 Battery Volts Displays battery voltage Go to 37
XX.XX VDC
37 Battery Status Displays if battery is within operating range Go to 38
GOOD (within high and low battery setpoints)
38 Batt Temperature Displays battery temperature if optional Go to 31
XXX º C battery temperature sensor is installed
MANUAL SCAN Menu:
40 Inverter/Charger/System Displays inverter status message Go to 41
SYSTEM OFF
41 APM Limit Displays APM setpoint Go to 42
XX Amps AC
42 Aux AC Input Displays if Aux AC Input is within voltage Go to 43
ERROR and frequency tolerance
43 System AC Volts Displays Aux AC input volts or Go to 44
XXX VAC inverter AC output volts
44 System AC Amps Displays Aux AC input amps or Go to 45
XXX Amps AC inverter AC output amps
45 Battery Volts Displays battery voltage Go to 46
XX.XX VDC
46 Battery Status Displays if battery is within operating range Go to 47
GOOD (between high and low battery setpoints)
47 Batt Temperature Displays battery temperature if optional Go to 40