Owner`s manual

TSR-2 Remote Control
TruSine 4.5 kW Inverter Page 12 Owners Manual
The TSR-2 Remote uses a menu approach to select desired system functions. When menu command
messages are shown on the display, the operator may select the desired function by pressing the
corresponding control button. Press the ESC (Escape) button at any time to step back one level. Press the
MENU button at any time to return to the Main Menu.
The MAIN MENU and all submenus are structured as follows:
MAIN MENU
BASIC CONTROL
MONITOR
AUTOSCAN (display)
MANUAL SCAN (display)
GENERAL INFO (display)
ADVANCED CONTROL
ADVANCED CONTROL
COMMUNICATIONS
The MAIN MENU is made up of the following two displays. Select the arrows to scroll up or down.
BSCONTROL ALARMS
MONITOR
GENERAL INFO
ADV CONTROL
Select the BSCONTROL (BASIC CONTROL) submenu from the first display by pressing the upper left Control
Button. The TSR-2 will then display the BASIC CONTROL submenu which is Step 10. The following figure
shows Step 10 and describes how the buttons on the TSR-2 work while Step 10 is displayed.
Step 10 from the Control Menu
INVERTER
ENABLED disabled
MENUESC
PUSH TO SCROLL UP
PUSH TO ENABLE
PUSH TO GO BACK
ONE MENU LEVEL
PUSH TO RETURN
TO MAIN MENU
PUSH TO DISABLE
PUSH TO SCROLL DOWN
(SHOWN ENABLED)
Adjustable Contrast Control
The TSR-2 Display has an adjustable contrast control. To increase intensity: hold down the lower left control
button and press the upper right control button repeatedly until the desired level is obtained. To decrease
intensity: hold down the lower left control button and press the lower right control button repeatedly until the
desired contrast level is obtained.
Demo Mode
Use Demo Mode to become familiar with the TSR-2 menu sequences. The TSR-2 is placed in Demo Mode by
connecting the Data Cable while both the Escape button and the Menu button are held down. Discontinue
Demo Mode by disconnecting the data cable.
If someone accidentally changes the Inverter Address, Step 92, the TSR-2 immediately will stop responding.
Use Demo Mode to reset Step 92 ‘Inverter Address’ to 1. The Communication Addresses are the only settings
selected in Demo Mode which carry back to normal operation.
Placing changes into effect
The only changes which go into effect without resetting the system are ‘enabling or disabling’ the inverter and