Installation manual

Specifications and Features
2-3
Copyright
2001 Phone: (614) 771-271 RE-4500
Vanner Inc. FAX: 614-771-4904 Installation Manual
4282 Reynolds Dr. www.vanner.com Rev 10d
Hilliard Ohio 43026 RE Owners_Manual_Rev10d D99988
INCORPORATED
INCORPORATEDINCORPORATED
INCORPORATED
Temperature in Degrees C
5000
4500
4000
3500
3000
2500
2000
1500
1000
500
Watts (Output)
Operating Range
-50 -40
-30 -20 -10 0 10 20 30 40 50 60
70 80
18.75 Arms
28.13 Arms
37.50 Arms
56.25 Arms
79.55 Arms
0.0000514
Seconds
10
Seconds
3
Seconds
1 Second
.01667
seconds
Indefinitely
*Note:
The RE-4500 Inverter will try to power the load as per the chart
above. When the load exceeds the inverter's rated output the
Inverter/Charger Indicator LED will turn Orange. The current limit
circuit will operate in the manner indicated above, and will reduce the
AC Output Voltage as needed to keep the AC Output Current from
exceeding specifications. If the output voltage is outside the limits
shown in Chart 2-3, the inverter will shut off and the Inverter/Charger
LED will turn Red.
Chart 2-1: Inverter Power De-Rating Chart*
Chart 2-2: Output Current Surge Fault Response Time @ 25°C*